Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix:
PLAT
ID:
0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the
backplane.
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive. b. Cable from the system board to the backplane. c. Hard disk
drive backplane. (n = hard disk drive number)
•
806f020d-0405ffff : Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive 5)
This message is for the use case when an implementation has detected an Array Failure is Predicted.
May also be shown as 806f020d0405ffff or 0x806f020d0405ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix:
PLAT
ID:
0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the
backplane.
482
System x3550 M4 Installation and Service Guide
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......