816f000d-0406ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 6)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0406ffff or 0x816f000d0406ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix:
PLAT
ID:
0163
User Response
1. Reseat hard disk drive n.(n = hard disk drive number). Wait 1 minute or more before reinstalling
the drive.
2. Replace the hard disk drive.
3. Make sure that the disk firmware and RAID controller firmware are at the latest level.
4.
Check the SAS cable.
•
816f000d-0407ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName]. (Drive 7)
This message is for the use case when an implementation has detected a Drive has been Removed.
May also be shown as 816f000d0407ffff or 0x816f000d0407ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
656
System x3550 M4 Installation and Service Guide
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......