Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0245
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Replacing the system board). (n = microprocessor number)
•
816f0a13-0302ffff : System [ComputerSystemElementName] has recovered from a Fatal Bus
Error. (CPU 2 PECI)
This message is for the use case when an implementation has detected that a system has recovered
from a Bus Fatal Error.
May also be shown as 816f0a130302ffff or 0x816f0a130302ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0245
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
784
System x3550 M4 Installation and Service Guide
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......