Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Check the Ethernet cable for damage and ensure correct cable type and attachment.
2. Check component firmware level and upgrade if necessary. The installed firmware level can be
found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
3. Rerun the test.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
–
–
–
DSA LSI hard drive test results
The following messages can result when you run the LSI hard drive test.
Test results for the DSA LSI hard drive test
The following messages can result when you run the DSA LSI hard drive test.
•
407-000-000 : LSIESG:DiskDefaultDiagnostic Test Passed
The test passed.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
–
–
–
•
407-800-000 : LSIESG:DiskDefaultDiagnostic Test Aborted
854
System x3550 M4 Installation and Service Guide