Figure 157. ServeRAID memory module removal
If you are instructed to return the memory module, follow all packaging instructions, and use any packaging
materials for shipping that are supplied to you.
Replacing the ServeRAID adapter memory module
Use this information to replace the ServeRAID adapter memory module.
To install the ServeRAID adapter memory module, complete the following steps:
Step 1.
Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 31.
Step 2.
Turn off the server and peripheral devices and disconnect all power cords.
Step 3.
Remove the cover (see “Removing the cover” on page 189).
Step 4.
Remove the ServeRAID SAS/SATA controller (see “Removing a ServeRAID SAS/SATA controller”
on page 230).
Step 5.
Align the memory module with the connector on the ServeRAID adapter and push it into the
connector until it is firmly seated.
Figure 158. ServeRAID memory module installation
Removing and replacing components
237