Step 6.
Reinstall the ServeRAID SAS/SATA controller (see “Replacing a ServeRAID SAS/SATA controller”
on page 231).
Step 7.
Reconnect the power cords and any cables that you removed.
Step 8.
Reinstall the cover (see “Replacing the cover” on page 190).
Step 9.
Slide the server into the rack.
Step 10. Turn on the peripheral devices and the server.
Removing the dual-port network adapter
Use this information to remove the dual-port network adapter.
To remove the dual-port network adapter, complete the following steps:
Step 1.
Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 31.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3.
Remove the cover (see “Removing the cover” on page 189).
Step 4.
Remove the PCI riser-card assembly (if installed) from PCI riser connector 2 (see “Removing a PCI
riser-card assembly” on page 220).
Step 5.
Loosen the two captive screws on the network adapter from the screw holes on the system board.
Figure 159. Screws disengagement
Step 6.
Loosen the thumbscrew on the chassis.
Step 7.
Grasp the network adapter and disengage it from the pin, retention brackets, and the connector on
the system board; then, lift the adapter out of the port openings on the rear of the chassis and
remove it from the server.
238
System x3550 M4 Installation and Service Guide
Summary of Contents for x3550 M4
Page 1: ...System x3550 M4 Installation and Service Guide Machine Type 7914 ...
Page 6: ...iv System x3550 M4 Installation and Service Guide ...
Page 178: ...164 System x3550 M4 Installation and Service Guide ...
Page 322: ...308 System x3550 M4 Installation and Service Guide ...
Page 828: ...814 System x3550 M4 Installation and Service Guide ...
Page 986: ...972 System x3550 M4 Installation and Service Guide ...
Page 990: ...976 System x3550 M4 Installation and Service Guide ...
Page 1005: ......
Page 1006: ......