S.2018001 An Uncorrected PCIe Error has Occurred at Bus [arg1] Device [arg2] Function [arg3].
The Vendor ID for the device is [arg4] and the Device ID is [arg5]. PCIe Uncorrected Error Detected
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver
and any required firmware updates.
2. If this node and/or any attached cables were recently installed, moved, serviced or upgraded, a.
Reseat Adapter and any attached cables. b. Reload Device Driver c. If device is not recognized,
reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2 settings can be configured
via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe Gen1/Gen2/Gen3 Speed
Selection, or the ToolsCenter Suite CLI Utility.
3. If problem persists, then remove Adapter Card. If system reboots successfully without the
adapter, replace that card.
4. (Trained Service technician only) Replace the system board.
5. (Trained Service technician only) Replace the processor.
•
S.3020007 A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault
Detected, System halted
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that
applies to this error.
2.
Update the UEFI image.
3. (Trained service technician only) Replace the system board.
•
S.3028002 Boot permission timeout detected. Boot Permission Negotiation Timeout
Explanation:
Severity
Error
User Response
Complete the following steps:
1. Check CMM/IMM logs for communication errors and resolve.
2.
Reseat the system
3. If problem persists contact support
1136
Lenovo System x3650 M5 Installation and Service Guide
Summary of Contents for x3650 M5
Page 1: ...Lenovo System x3650 M5 Installation and Service Guide Machine Type 8871 ...
Page 47: ...Figure 35 System board switches jumpers and buttons Chapter 1 The System x3650 M5 server 35 ...
Page 60: ...48 Lenovo System x3650 M5 Installation and Service Guide ...
Page 80: ...68 Lenovo System x3650 M5 Installation and Service Guide ...
Page 124: ...112 Lenovo System x3650 M5 Installation and Service Guide ...
Page 146: ...134 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1322: ...1310 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1330: ...Taiwan BSMI RoHS declaration 1318 Lenovo System x3650 M5 Installation and Service Guide ...
Page 1339: ......
Page 1340: ......