Internal drive options

The following table lists hard drive options for internal disk storage of the x3755 M3 server. 

Table 9. Disk drive options for internal disk storage

Part

 

number

Feature
code

Description

Maximum
supported

Hot-swap SAS drives

44W2244

5313

600GB 15K 6Gbps SAS 3.5" Hot-Swap HDD

8

44W2239

5312

450GB 15K 6Gbps SAS 3.5" Hot-Swap HDD

8

44W2234

5311

300GB 15K 6Gbps SAS 3.5" Hot-Swap HDD

8

Hot-swap NL SAS drives

49Y6205

A4AG

4TB 7.2K 6Gbps NL SAS 3.5'' HS HDD

8

81Y9758

A281

3TB 7.2K 6Gbps NL SAS 3.5" HS HDD

8

42D0767

5417

2TB 7.2K 6Gbps NL SAS 3.5" HS HDD

8

42D0777

5418

1TB 7.2K 6Gbps NL SAS 3.5" HS HDD

8

Hot-swap NL SATA drives

49Y6185

A3WB

4TB 7.2K 6Gbps NL SATA 3.5" HS HDD

8

81Y9774

A27Z

3TB 7.2K 6Gbps NL SATA 3.5" HS HDD

8

42D0782

5415

2TB 7200 NL SATA 3.5" HS HDD

8

Hot-swap SATA drives

43W7626

5560

1TB 7200 SATA 3.5'' HS HDD

8

39M4530

5196

500GB 7200 RPM 3.5" Hot-Swap SATA II

8

Simple swap drives

81Y9778

A280

3TB 7.2K 6Gbps NL SATA 3.5" SS HDD

6

42D0787

5416

2TB 7200 NL SATA 3.5" SS HDD

6

43W7622

5559

1TB 7.2K SATA 3.5" Simple-Swap HDD

6

39M4514

5288

500GB 7200 RPM 3.5" Simple-Swap SATA II

6

Internal backup units

The x3755 M3 server with simple-swap drives can physically house an internal tape drive. However, the 

supported tape drive has been withdrawn from marketing. As a result the x3755 M3 cannot be configured 

with an internal tape drive.

Summary of Contents for x3755 M3

Page 1: ...s reduce networking complexity and cost for high performance computing environments and the available 32 TB of internal storage facilitates data intensive applications like business intelligence Figure 1 shows the System x3755 M3 Figure 1 The System x3755 M3 Did you know The System x3755 M3 fits into 2U of standard rack space and it can be used as a very affordable dual socket 2U rack platform wit...

Page 2: ...55 M3 2 Locations of key components and connectors Figure 2 shows the front of the server Figure 2 Front view of the System x3755 M3 Figure 3 shows the rear of the server Figure 3 Rear view of the System x3755 M3 ...

Page 3: ...System x3755 M3 3 Figure 4 shows the locations of key components inside the server Figure 4 Inside view of the System x3755 M3 shown with the power supply cage and air baffle removed ...

Page 4: ...Up to 128 GB with 4 GB DDR3 UDIMMs and four processors Memory protection ECC Chipkill for x4 based and x8 based memory DIMMs and memory sparing Disk drive bays Up to six 3 5 simple swap SS SATA HDDs CTO only or up to eight 3 5 hot swap HS SAS SATA HDDs Maximum internal storage Up to 32 TB with 4 TB 3 5 HS NL SATA or NL SAS HDDs Up to 4 8 TB with 600 GB 3 5 HS SAS HDDs Up to 18 0 TB with 3 TB 3 5 S...

Page 5: ...lors Operating systems supported Microsoft Windows Server 2008 R2 and 2008 Red Hat Enterprise Linux 5 and 6 SUSE Linux Enterprise Server 10 and 11 VMware ESX 4 0 and 4 1 VMware ESXi 4 0 and 4 1 and vSphere 5 embedded hypervisor See the Supported operating systems section for specifics Limited warranty Three year customer replaceable unit and onsite limited warranty with 9x5 next business day respo...

Page 6: ...164 B2x 4x AMD Opteron 6276 16C 2 3 GHz 16 MB 115W 8x 4 GB M5015 Battery 8x 3 5 HS 8 Open 4x GbE Optional 1x 1100W HS 3 7164 D2x 4x AMD Opteron 6272 16C 2 1 GHz 16 MB 115W 8x 4 GB M1015 8x 3 5 HS 8 Open 4x GbE Optional 1x 1100W HS 3 7164 G2x 4x AMD Opteron 6234 12C 2 4 GHz 16 MB 115W 8x 4 GB M1015 8x 3 5 HS 8 Open 4x GbE Optional 1x 1100W HS 3 7164 J2x 4x AMD Opteron 6220 8C 3 0 GHz 16 MB 115W 8x ...

Page 7: ...on 6376 16C 2 3 GHz 16MB 115W 1600 MHz 00AM125 A4MQ A4N0 AMD Opteron 6378 16C 2 4 GHz 16MB 115W 1600 MHz 00AM123 A4MN A4MY AMD Opteron 6380 16C 2 5 GHz 16MB 115W 1600 MHz F3x 00AM124 A4MP A4MZ AMD Opteron 6386SE 16C 2 8 GHz 16MB 140W 1600 MHz AMD Opteron 6200 series processors 90Y5355 A1T8 A1TZ AMD Opteron 6212 8C 2 6 GHz 16MB 115W 1333 MHz 90Y5358 A1TB A1U2 AMD Opteron 6220 8C 3 0 GHz 16MB 115W 1...

Page 8: ...IMMs 46W0779 A4Z5 16GB 1x16GB 2Rx4 1 5V PC3 14900 CL13 ECC DDR3 1866MHz LP RDIMM 32 46W0771 A4RC 8GB 1x8GB 1Rx4 1 35V PC3L 12800 CL11 ECC DDR3 1600MHz LP RDIMM 32 F3x Table 5 Memory options for systems with AMD Opteron 6200 processors Part number Feature code Description Maximum supported Models where used UDIMMs 49Y1404 8648 4GB 1x4GB 2Rx8 1 35V PC3L 10600 CL9 ECC DDR3 1333MHz LP UDIMM 32 RDIMMs ...

Page 9: ...and operating voltage as shown in the Max qty supported row in the following table All DIMMs in the server operate at the same speed which is determined as the lowest value of Memory speed that is supported by the specific CPU Lowest of maximum operating speeds for selected memory configuration that depends on rated speed operating voltage and quantity of DIMMs per channel as shown under Maximum o...

Page 10: ...ms with AMD Opteron 6200 processors DIMM specification UDIMM RDIMM Rank Dual rank Single rank Dual rank Quad rank Part numbers 49Y1404 4 GB 49Y1406 4 GB 49Y1405 2 GB 46C7449 8 GB 49Y1435 4 GB 49Y1400 16 GB Rated speed 1333 MHz 1333 MHz 1333 MHz 1066 MHz Rated voltage 1 35 V 1 35 V 1 5 V 1 35 V Operating voltage 1 35 V 1 5 V 1 35 V 1 5 V 1 5 V 1 35 V 1 5 V Max qty supported 32 32 32 32 32 32 32 Max...

Page 11: ...mote Mount Cable 1 49Y4731 ServeRAID BR10il SAS SATA Controller v2 1 The RAID controller is installed into dedicated PCI E slot 4 Figure 4 Simple Swap SATA models only support the ServeRAID BR10il v2 controller The BR10il v2 supports up to four SS SATA HDDs and the remaining two SATA HDDs can be used as standalone drives that are not part of a RAID array Hot swap SAS SATA models do not support Ser...

Page 12: ...ey 6 Gbps throughput per port PCI Express 2 0 x8 host interface Based on the LSI SAS2108 6 Gbps ROC controller 256 MB of onboard cache Optional Intelligent Li Ion based battery backup unit with the ServeRAID M5000 Series Battery Kit The ServeRAID M5015 SAS SATA Controller has the following specifications Two Mini SAS internal connectors Supports RAID levels 0 1 5 10 and 50 Supports RAID 6 and 60 w...

Page 13: ...42D0777 5418 1TB 7 2K 6Gbps NL SAS 3 5 HS HDD 8 Hot swap NL SATA drives 49Y6185 A3WB 4TB 7 2K 6Gbps NL SATA 3 5 HS HDD 8 81Y9774 A27Z 3TB 7 2K 6Gbps NL SATA 3 5 HS HDD 8 42D0782 5415 2TB 7200 NL SATA 3 5 HS HDD 8 Hot swap SATA drives 43W7626 5560 1TB 7200 SATA 3 5 HS HDD 8 39M4530 5196 500GB 7200 RPM 3 5 Hot Swap SATA II 8 Simple swap drives 81Y9778 A280 3TB 7 2K 6Gbps NL SATA 3 5 SS HDD 6 42D0787...

Page 14: ...llowing media and speeds for reading CD ROM 24X CD DA DAE 20X CD R 24X CD RW 24X DVD ROM single layer 8X DVD ROM dual layer 8X DVD R 4 7 GB 6X DVD R DL 4X DVD R 6X DVD R DL 4X DVD RW 4 7 GB 4X DVD RW 4X DVD RAM 4 7 9 4 GB 4X The UltraSlim Enhanced SATA Multi Burner part number 46M0902 supports the same media and speeds for reading as DVD ROM 46M0901 In addition this drive supports the following me...

Page 15: ...card The slot form factors are Slot 1 PCIe 2 0 x16 full height full length Slot 2 PCIe 2 0 x8 low profile half length Slot 3 PCIe 2 0 x8 x4 wired low profile half length Slot 4 PCIe 2 0 x8 low profile half length internal only reserved for RAID controller Figure 5 shows the location of the adapter slots on a riser card Figure 5 Adapter slots in the x3755 M3 ...

Page 16: ...49Y4230 5767 Intel Ethernet Dual Port Server Adapter I340 T2 for System x 3 49Y7960 A2EC Intel X520 Dual Port 10GbE SFP Adapter for System x 3 81Y3520 AS73 Intel X710 2x10GbE SFP Adapter for System x 3 81Y9990 A1M4 Mellanox ConnectX 2 Dual Port 10GbE Adapter for System x 3 00D9690 A3PM Mellanox ConnectX 3 10 GbE Adapter for System x 3 42C1800 5751 QLogic 10Gb CNA for System x 3 1 Gb Ethernet adapt...

Page 17: ... 16Gb FC Dual port HBA for System x 3 00Y3337 A3KW QLogic 16Gb FC Single port HBA for System x 3 00Y3341 A3KX QLogic 16Gb FC Dual port HBA for System x 3 Fibre Channel 8 Gb 46M6049 3589 Brocade 8Gb FC Single port HBA for System x 3 46M6050 3591 Brocade 8Gb FC Dual port HBA for System x 3 42D0485 3580 Emulex 8Gb FC Single port HBA for System x 3 42D0494 3581 Emulex 8Gb FC Dual port HBA for System x...

Page 18: ...e power supplies can be installed with the third redundant N 1 where N 2 If four 140W processors are installed only one power supply can be installed with no redundancy or two power supplies can be installed with the second redundant N 1 where N 1 provided these limits are met Maximum 16 DIMMs Maxumum 4 disk drives The server comes standard with one or two power supplies depending on the model The...

Page 19: ...y Key for VMware ESXi 4 1 Update 1 1 41Y8287 3033 USB Memory Key for VMware ESXi 4 1 1 41Y8278 1776 USB Memory Key for VMware ESXi 4 1 Remote management The server contains second generation Integrated Baseboard Management Controller iBMC which provides advanced service processor control monitoring and an alerting function If an environmental condition exceeds a threshold or if a system component ...

Page 20: ...at Enterprise Linux 7 SUSE LINUX Enterprise Server 11 for AMD64 EM64T SUSE LINUX Enterprise Server 11 with Xen for AMD64 EM64T SUSE Linux Enterprise Server 12 SUSE Linux Enterprise Server 12 with XEN VMware vSphere 5 1 ESXi VMware vSphere 5 5 ESXi The following operating systems are supported on models with AMD Opteron 6200 processors Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008 ...

Page 21: ... m 3 000 ft Server on 10 32 C 50 90 F altitude 915 m 3 000 ft 2 134 m 7 000 ft Server off 10 43 C 50 109 F Humidity Server on 8 80 Server off 8 80 Electrical 100 127 nominal V ac 50 Hz or 60 Hz 19 0 A 200 240 nominal V ac 50 Hz or 60 Hz 11 6 A Input kilovolt amperes kVA approximately Minimum configuration 0 20 kVA Maximum configuration 2 17 kVA Btu output Ship configuration 648 Btu hr 190 watts Fu...

Page 22: ...r customer s location within four hours after remote problem determination is completed We provide service around the clock every day including Lenovo holidays 9x5x4 hour A service technician is scheduled to arrive at your customer s location within four business hours after remote problem determination is completed We provide service from 8 00 a m to 5 00 p m in the customer s local time zone Mon...

Page 23: ...A Australia New Zealand AS NZS CISPR 22 Class A IEC 60950 1 2001 CB Certificate and CB Test Report Taiwan BSMI CNS 13438 Class A CNS 14336 China CCC GB4943 GB9254 Class A GB17625 1 Korea KN22 Class A KN24 Russia GOST ME01 IEC 60950 1 GOST R 51318 22 99 GOST R 51318 24 99 GOST R 51317 3 2 2006 GOST R 51317 3 3 99 IEC 60950 1 CB Certificate and CB Test Report CE Mark EN55022 Class A EN60950 1 EN5502...

Page 24: ...l Enclosure 2071CU3 IBM Storwize V3500 SFF Dual Control Enclosure 6099L2C IBM Storwize V3700 3 5 inch Storage Controller Unit 6099S2C IBM Storwize V3700 2 5 inch Storage Controller Unit 6099T2C IBM Storwize V3700 2 5 inch DC Storage Controller Unit 6194L2C IBM Storwize V5000 LFF Control Enclosure 6194LEU IBM Storwize V5000 LFF Expansion Enclosure 6194S2C IBM Storwize V5000 SFF Control Enclosure 61...

Page 25: ...0 Dock with 1TB Cartridge 49Y9898 Half High LTO Gen 5 Internal SAS Tape Drive 00D8924 Half High LTO Ultrium Gen 6 Internal SAS Tape Drive External backup units 362532Y RDX External USB 3 0 Dock with 320GB Cartridge 362550Y RDX External USB 3 0 Dock with 500GB Cartridge 36251TY RDX External USB 3 0 Dock with 1TB Cartridge 3628L5X Half High LTO Gen 5 External SAS Tape Drive with US line cord 3628N5X...

Page 26: ...052F 10 Gb top of rack switches 7309DRX RackSwitch G8264CS Rear to Front 7309DFX RackSwitch G8264CS Front to Rear 7309BR6 RackSwitch G8124ER 7309BF7 RackSwitch G8124EF 7309G64 RackSwitch G8264R 730964F RackSwitch G8264F 7309CR9 RackSwitch G8264TR 7309CF9 RackSwitch G8264TF 40 Gb top of rack switches 8036BRX RackSwitch G8332 Rear to Front 8036BFX RackSwitch G8332 Front to Rear 8036ARX RackSwitch G8...

Page 27: ...55946KX RT6kVA 3U Rack or Tower UPS 200 240VAC 55948KX RT8kVA 6U Rack or Tower UPS 200 240VAC 55949KX RT11kVA 6U Rack or Tower UPS 200 240VAC 55948PX RT8kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC 55949PX RT11kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC Rack mounted UPS units 53951AX 1500VA LCD 2U Rack UPS 100V 120V 53951KX 1500VA LCD 2U Rack UPS 230V 53952AX 2200VA LCD 2U Rack UPS 100V 120V 53...

Page 28: ...7 0U 12 C19 12 C13 Switched and Monitored 32A 3 Phase PDU Enterprise PDUs 71762MX Ultra Density Enterprise PDU C19 PDU WW 71762NX Ultra Density Enterprise PDU C19 PDU WW 71763MU Ultra Density Enterprise PDU C19 3 phase 60A PDU NA 71763NU Ultra Density Enterprise PDU C19 3 phase 60A PDU NA 39M2816 DPI C13 Enterprise PDU without linecord 39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P ...

Page 29: ...Universal Rack PDU w UK LC 39Y8958 DPI Universal Rack PDU with AS NZ LC 39Y8959 DPI Universal Rack PDU w China LC 39Y8962 DPI Universal Rack PDU Argentina 39Y8960 DPI Universal Rack PDU Brazil 39Y8961 DPI Universal Rack PDU India 0U Basic PDUs 46M4122 0U 24 C13 16A 3 Phase PDU 46M4125 0U 24 C13 30A 3 Phase PDU 46M4128 0U 24 C13 30A PDU 46M4131 0U 24 C13 32A PDU 46M4140 0U 12 C19 12 C13 60A 3 Phase...

Page 30: ... Rack 93604EX 42U 1200 mm Deep Dynamic Expansion Rack 93604PX 42U 1200 mm Deep Dynamic Rack 93614EX 42U 1200 mm Deep Static Expansion Rack 93614PX 42U 1200 mm Deep Static Rack 93624EX 47U 1200 mm Deep Static Expansion Rack 93624PX 47U 1200 mm Deep Static Rack 14104RX Linux Cluster Rack For more information see the list of Product Guides in the Rack cabinets and options category http www redbooks i...

Page 31: ...4D2X 1754HC2 fc 6695 Global 4x2x32 Console Manager GCM32 1754D1X 1754HC1 fc 6694 Global 2x2x16 Console Manager GCM16 1754A2X 1754HC4 fc 0726 Local 2x16 Console Manager LCM16 1754A1X 1754HC3 fc 0725 Local 1x8 Console Manager LCM8 Console cables 43V6147 3757 Single Cable USB Conversion Option UCO 39M2895 3756 USB Conversion Option 4 Pack UCO 39M2897 3754 Long KVM Conversion Option 4 Pack Long KCO 46...

Page 32: ...ms processes and flexible policies support our goal of providing customers with a positive experience We finance your entire solution Unlike others we allow you to bundle everything you need from hardware and software to service contracts installation costs training fees and sales tax If you decide weeks or months later to add to your solution we can consolidate everything into a single invoice Ou...

Page 33: ...t entry portal docdisplay lndocid MIGR 5085682 System x 3755 M3 Problem Determination and Service Guide http ibm com support entry portal docdisplay lndocid MIGR 5085681 ServerProven hardware compatibility page for the x3755 M3 http ibm com systems info x86servers serverproven compat us xseries 7164 html Configuration and Option Guide http www ibm com systems xbc cog xREF x86 Reference Sheets http...

Page 34: ...cation Lenovo may make improvements and or changes in the product s and or the program s described in this publication at any time without notice The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo pro...

Page 35: ...ormation was published Such trademarks may also be registered or common law trademarks in other countries A current list of Lenovo trademarks is available on the Web at http www lenovo com legal copytrade html The following terms are trademarks of Lenovo in the United States other countries or both Lenovo RackSwitch Lenovo logo ServeRAID ServerGuide ServerProven System x The following terms are tr...

Reviews: