Important Considerations For Installation

Electrical Service

Water Supply

All plumbing connections must conform to local codes. 
Water supply to the spa should be provided with adequate water pressure and water temperature.

Water pressure

To fill the basin correctly up to level, Normal water pressure of 30 to 80 P.S.I is required.

Water temperature

The hot water supply temperature must not exceed 140  . Adjust your hot water accordingly. For hot and cold water supply 
fittings and drain fittings location, see below diagram .Carefully connect the water supply line to the appropriate fittings 
located on the rear of the pedicure spa.

The pedicure spa Drain must meet local plumbing codes. 

Check valve for Drain (not Provided) Must be installed by a licensed 

plumber.

 Also Pedicure spa must be securely fasten to the floor.

UL LISTED / CE CERTIFIED

Compliance with following Code (s): Uniform Plumbing Code, National Plumbing Code of Canada and international 
Plumbing Code. Also, Compliance with following Standard (s): ASME A112.18.3M / A112.18.1M, CSA B125, NSF / 
ANSI 61

Drain Facilities

ANSI - American National Institute,  ASME - American Society of Mechanical Engineers, CSA - Canadian Standard 
Association IAPMO - International Association of Plumbing and Mechanical Officials, UL - Underwriters Laboratory

110V, 60Hz, 15Amp GFCI protected grounded circuit MUST be used to supply power each individual pedicure spa. 
And the main circuit breaker MUST be at 25Amp. 

Pressure / Temperature

Maximum Pressure: 150 psi (10 bars)
Minimum Pressure: 10 psi (69kPa)
Working Temperature: 33F to 140F constant; intermittent to 180f
                                        (0.6C to 60C sustained; intermittent to 82.2C)
Maximum Recommended Flow: 1.5gpm 

   Due to Town and / or State requirement/s are varies in building code, if the Town and / or State requires 
   Vaccum Breaker, As the Plumber MUST provide Vaccum Breaker according to building code 
   requirement.  

Installation Summary

The installation must comply with local, state, and federal building, plumbing and electrical codes, where applicable. A 
licensed plumber should complete the plumbing of the pedicure spa.

Note: Failure to comply with federal, state, or local codes and ordinances will result in warranty being nullified and 
void.

** Backflow Protection device

All J&A USA products has been compliance with requirements for Whirlpool bath appliances contained in ASME / ANSI 
A122.19.7M-1995, CSA C22.2 No. 68-69 

Summary of Contents for MS

Page 1: ...OWNER S MANUAL L E N O X Please read user s Manual thoroughly before using pedicure spa MS ...

Page 2: ...n summary Space Requirement Power Discharge Pump Pipeless Whirlpool motor Base inner structure Massage Remote control functions Massage Mechanism Chair back rest Holding Mech Trouble Shooting Disinfecting Pedicure Spa User s Recommendation UL Certification Backflow Protection Device JSG Oceana Implied Warranty Limited Warranty 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 21 22 23 24 25 26 27 28 ...

Page 3: ...uct Yes No Yes No Yes No Yes No Year s Year s Year s 4 What is the most important features in choosing Pedicure Spa Brand Design Function Service 1 Are you satisfy with Pedicure spa received Price Other 5 How long in business 6 How often are you remodel Your Salon 9 Any suggestion or Comment Limited Warranty Registration Form 8 Do you want to receive a promotion by email To validate the limited wa...

Page 4: ...______________________ _______________________________________________________________________________________ Phone Number ____________________________________ Alternate Phone Number ___________________________ Contact Person ____________________________________ Best time to reach ________________________________ Serial Number ____________________________________ Brief Description of Problem ____...

Page 5: ...Lenox Lenox J 41 5 ...

Page 6: ...rican National Institute ASME American Society of Mechanical Engineers CSA Canadian Standard Association IAPMO International Association of Plumbing and Mechanical Officials UL Underwriters Laboratory 110V 60Hz 15Amp GFCI protected grounded circuit MUST be used to supply power each individual pedicure spa And the main circuit breaker MUST be at 25Amp Pressure Temperature Maximum Pressure 150 psi 1...

Page 7: ...Open Close Air Activate On Off Button Single lever Faucet Tray Post Glass tray Remote Control Glass bowl Borosilicate Arch Footrest post Mech 3 Separated Foot Cushion Adjustable Center foorest Glass Bowl Housing Press button to adjust desire height Fixed footrest Height Fixed footrest Height Shower Holder Pipe less Whirlpool motor ...

Page 8: ... x 33 W x 55 H 380 Lbs 4 5 U S Gallons On Off Air Activated Switch 115 Vac 60Hz 15 Amp 120 Vac 60Hz 0 5 inches Fitting Provided 0 5 inches Fitting Provided 1 5 inches See detailed instruction One year Parts and labor Due to continuous improvement on all our products followings are subject to change without notice specification characteristics packing information color and design All J A products a...

Page 9: ...LENOX MS Dimension 68 12 5 12 5 28 33 27 17 33 55 1 2 21 Note All dimensions are approximate 4 ...

Page 10: ...Wall Drain Drain AConnection Discharge Pump ...

Page 11: ...15 tilt ...

Page 12: ...20Vac GFI Protected Hot and Cold Water Hot and Cold Water Inlet 1 2 Drain OutLet 1 1 2 PVC Pipe Check Valve Shut Off Valves GFCI Optional Discharge pump Top Rear View Space Requirement Space Req for Swivel to Side to Side ...

Page 13: ... P pump insert into 2 Min Timer Make sure to push in tightly PLUMBER MUST BE UTILIZED TO INSTALL CHECK VALVE DRAIN OUTLET MUST BE FOR EFFICIENT DRAINAGE SMALL Rubber Coupling Elbow LARGE Rubber Coupling LARGE Rubber Coupling 3 4 PVC Pipe HANNING DPO 40 020 3 4 Elbow Rubber Gasket 3 4 PVC Pipe 3 4 PVC Pipe 3 4 SLIP X Male Adaptor TEE 3 4 X 3 4 X Poly Insert 90 Elb Clear Tubing 3 4 OD ID Air Check V...

Page 14: ...stream 2 Magnetic whirlpool jet cover can be remove for quick cleaning and sanitizing 3 Built In electronic sensor for pump control 4 AC Whirlpool motor long life 5 Very low power consumption 27W 6 Manufactured in USA 1 Turn off the unit and wait until the motor is fully stops 2 Hold Hydro whirlpool jet cover firmly and pull to separate from the round magnetic field 3 Turn hydro whirlpool jet cove...

Page 15: ... FILL THE WATER TO WATER LEVEL INDICATOR 2 HOLD MAGNETIC JET FIRMLY TO BRING CLOSER TO THE ROUND MAGNETIC FILED AND DO NOT RELEASE THE MAGNETIC JET PREMATURELY OR THIS WILL CAUSE IMPACTS ON THE JET COVER AND THE ROUND MAGNETIC FIELD HOUSING SHORTENING THE LIFE EXPECTANCY OF THE JET COVER WHEN THE JET COVER NEARS THE ROUND MAGNETIC FIELD PLACE JET COVER ONTO THE FOUR DIMMPLE AREA SEE DIAGRAM THE JE...

Page 16: ... off and wait until the motor is fully stops 2 Remove the front jet cover and notice the locking screw in the center 3 Remove the locking center screw turn counter clockwise and pull out impeller from housing 4 Use Anti Bacterial solution EPA Registered to clean all part s 5 After sanitization place impeller onto the motor shaft and fasten with center locking screw Turn clockwise DURA JET III Spec...

Page 17: ...Top View Perspective View Bottom View Side View Rear View Metal Mesh tray off the floor ...

Page 18: ...ion POSITION User s Height HIGH MID LOW WHEEL Adjust Massage Wheels Up and Down to desirable position MANUAL Press for Manual MODE with Time Selection of 10 30 Mins RANGE FULL PARTIAL SPOT 3 Selections MSG Keep Pressing to Massage Wheel to the intended Massage Width COMB Kneading Tapping Knocking Combinations TAP 3 Slections of Tapping intensity SHIATSU 1 Press Manual Timer to choose Shiatsu Massa...

Page 19: ... Guide Roller Belt Pulley Kneading Belt DC Motor Kneading DC Motor Tapping Up and Down Gear Box DC Motor Travel Belt Pulley Travel Belt Tapping Belt Massage Arm extension Rod w ball extension Main PCB Transformer Bracket For Backrest Travel Sensor Main Remote Control 2nd Slide recline remote Control slot PCB Fuse Vibration Grn Yel Red Recliner White Slider D C Motors Board Holders Power PCB Case W...

Page 20: ...position 1 Pull latch upward to release Red Black White Green Color code Receptacle Connection location Under Seat Cushion Red Tilting Up Down White Slide forward and back Green Seat Vibration Black 2nd remote Top View Seat Frame ...

Page 21: ...mer And to black control box with air actuated 1 8 clear hose 6 If pump is not heard verify two minute timer Water Pressure is low and or not coming out The water sprayer is not working or very little water comes out of the sprayer 1 Verify if water utility valve is on 2 Check for loose water connections under the basin and at the rear of the basin 3 Check if sprayer screen is clear 4 Verify if wa...

Page 22: ...s is not breakage Just release pressure by lift body weight The roller moved up or down and then stop Auto timer will cause the rollers to move up to the top of the chair and sometimes roller pass secondary stopper and causes mis alignmentation of the roller 1 contact vendor or J A service for assistance The right and left rollers are out of alignment The rollers are designed to provide for altern...

Page 23: ......

Page 24: ...reatment or are feeling ill Your body shows any acute symptoms You have heart disease You are pregnant or having a menstrual period your doctor has ordered you to rest You have a back disorder resulting from an accident or disease You are diabetic You have service interruption in the circulation of the legs You have a high fever You have sensory disorders You have medical electrical device e g pac...

Page 25: ......

Page 26: ...ICE MANUFACTURER NEOPERL INC Waterbury CT DEVICE MODEL Dual Check Valve 1 2 x 2 NPT DEVICE SPECIFICATION TESTED AND CERTIFIED TO MEET NSF ANSE 61 372 Complies with ANSI ASME A112 18 3M A112 18 1M DEVICE PRESSURE MAXIMUM PRESSURE 150 PSI 10 BAR SERVICE PRESSURE 80 PSI DEVICE TEMPERATURE MAXIMUM TEMPERATURE 150F SERVICE TEMPERATURE 90F ALL MODELS OF PEDICURE SPA MENTIONED ABOVE ARE EQUIPPED WITH THE...

Page 27: ...receipt from the original consumer purchaser and must accompany all warranty claims Implied warranties including that of merchantability or fittness for a particular purpose are expressly limited in duration to the duration of this warranty JSG Oceana LLC disclaims any liability for special incidental or consequential damages Some States do not allow limitation on how long an implied warranty last...

Page 28: ...No distributor or other person has the right or authority to bind J A USA INC to changes to this limited warranty NO CONSEQUENTIAL INCIDENTAL CONTINGENT INDIRECT SPECIAL OR OTHER DAMAGES WILL BE ALLOWED This warranty is null and void if the pedicure spa is removed from its original installation or is not installed accordance with specifications of pedicure spa or national state or local codes regul...

Reviews: