CANopen
6
Parameter setting
6-16
L
BA2175 EN 2.0
6.3.3
Process-data assignments for 82XX
Process data telegram to controller
User data length: 8 byte
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Identifier
Control word
L-C0135
Low byte
Control word
L-C0135
High byte
Setpoint
L-C0046
Low byte
Setpoint
L-C0046
High byte
xx
xx
xx
xx
Byte 1
Bits 0 to 7 of the control word under C0135 are entered here
M
i f
ti
Byte 2
Bits 8 to 15 of the control word under C0135 are entered here (see chapter 6.3.4.1).
The bit description can be obtained from the Code Table.
More information
about process data
Byte 3
The frequency setpoint, which can also be written as parameter under C046, is entered here as process data word.
about process data
Byte 4
The frequency setpoint, which can also be written as parameter under C046, is entered here as process data word.
The normalisation differs from the setting under C046. It is a signed value, 24000 = 480 Hz.
Telegram
Byte 5
Telegram
Byte 6
No evaluation of these data anything possible
Byte 7
No evaluation of these data, anything possible
Byte 8
Control word: see chapter 6.3.4.1.
AIF
C0046
.B15
.B13
.B14
.B12
.B0
.B1
.B2
.B3
.B4
...
...
...
.B8
.B9
.B10
.B11
QSP
CINH
TRIP-SET
TRIP-RESET
16 bit
16 bit
0
JOG/
C046
0 1 1
0 1 0 1
PAR
DCB
CW/CCW
Control
word
2141LON010
Fig. 6-3
Access to control word and frequency setpoint in 82XX (fixed, see (
^
6-20) )
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com