CANopen
6
Parameter setting
6-38
L
BA2175 EN 2.0
6.4.1.19
1600
hex
: Receive PDO1 mapping parameter
With this object, parameter data can be received as PDO1.
Tip!
At present this functionality is not available. Depending on the subindex, the following values are
returned when reading the object:
Subind. 0 : value 4
hex
Subind. 1 - 4: value 10
hex
Index
[hex]
Subindex
Name
Data type
Authorisation Explanation
1600
0
Number of mapped objects in
PDOs
PDO mapping
Subindex 0: Max. supported subindex = 4
1
PDO mapping 1
ro
2
PDO mapping 2
ro
Read request of this object are responded
3
PDO mapping 3
Read request of this object are responded
by the value 10
hex
.
4
PDO mapping 4
by the value 10
hex
.
6.4.1.20
1601
hex
: Receive PDO2* mapping parameter
With this object, parameter data can be received as PDO2.
Tip!
At present this functionality is not available. Depending on the subindex, the following values are
returned when reading the object:
Subind. 0 : value 4
hex
Subind. 1 - 4: value 10
hex
*) Object not available for 82XX, 8200 vector and 93XX controllers.
Index
[hex]
Subindex
Name
Data type
Authorisation Explanation
1600
0
Number of mapped objects in
PDOs
PDO mapping
Subindex 0: Max. supported subindex = 4
1
PDO mapping 1
ro
2
PDO mapping 2
ro
Read request of this object are responded
3
PDO mapping 3
Read request of this object are responded
by the value 10
hex
.
4
PDO mapping 4
by the value 10
hex
.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: info@actechdrives.com