background image

EDB8210UE-V020
400753

Operating Instructions

Global Drive

Frequency Inverters
8210 HVAC Series

HVAC and Pump Drives

Power Range 0.75 - 11 kW

Typ Id.-

NR

Fer

t.-

Nr

Ser

ien-N

r.

Ein

gang

1

Ein

gang

2

Lenze

Postfach 101352 ,31763 HAMELN

Typ Id

.-N

R

Fer

t.-

Nr

Se

rie

n-N

r.

Ei

ngang1

Ei

ngang2

Lenze

Postfach 101352 ,31763 HAMELN

Show/Hide Bookmarks

Summary of Contents for 8210 HVAC Series

Page 1: ...equency Inverters 8210 HVAC Series HVAC and Pump Drives Power Range 0 75 11 kW Typ Id NR Fert Nr Serien Nr Eingang1 Eingang2 Lenze Postfach 101352 31763 HAMELN Typ Id NR Fert Nr Serien Nr Eingang1 Ein...

Page 2: ...s of the versions 33 821X E 1x 3x 8211 8218 Type Design E Enclosure IP20 IB Module Hardware level and index Software level and index Variant Explanation Corresponds to the German edition of 06 01 98 E...

Page 3: ...ives with 120 overload 3 7 3 4 2 Single drives with 150 overload 3 8 3 5 Analog plug in module 3 9 3 5 1 Features 3 9 3 6 Dimensions 3 10 3 6 1 Controller dimension 3 10 3 6 2 Analog plug in module 3...

Page 4: ...misation of motor current control 5 10 5 5 Operation with the PID controller 5 12 5 5 1 Standardisation of a process value 5 13 5 6 Application examples 5 15 5 6 1 Air conditioning 5 15 5 6 2 Pump app...

Page 5: ...ncy inverter Drive system Drive systems with 82XX frequency inverters and other Lenze drive components 1 1 2 Changes in these Operating Instructions Material No Edition Important Contents 398945 01 10...

Page 6: ...ial premises The user is responsible for the compliance of his application with the EC directives Any other use shall be deemed inappropriate Liability The information data and notes in these Operatin...

Page 7: ...s compliance with the EMC Directive 89 336 EEC The drive controllers meet the requirements of the Low Voltage Directive 73 23 EEC The harmonized standards of the prEN 50178 DIN VDE 0160 series togethe...

Page 8: ...e prevention of accidents etc Modifications of the drive controllers by the operating software are allowed After disconnecting the drive controllers from the supply voltage live parts of the controlle...

Page 9: ...ences if disregarded Death or very severe injuries Warning of a general danger Warning Warns of potential very hazardous situations Possible consequences if disregarded Death or very severe injuries C...

Page 10: ...s Protection of devices Cyclic connection and disconnection of the controller supply voltage at L1 L2 L3 or UG UG may overload the internal input current load Allow at least 3 minutes between disconne...

Page 11: ...Cv 21 Limit value class A to EN 55011 industrial area with mains filter Limit value class B to EN 55022 residential area with mains filter and installation into control cabinet Noise immunity Limit va...

Page 12: ...212 E V020 EVF8213 E V020 EVF8214 E V020 Mains voltage Vrated V 320 V 0 Vrated 440 V 0 45 Hz 65 Hz 0 Alternative DC supply VDC V 450 V 0 VDC 620 V 0 Mains current with mains filter mains choke Imains...

Page 13: ...uency Digital setpoint selection Accuracy 0 05 Hz Analog setpoint selection Linearity 0 5 max selected signal level 5 V or 10 V Analog setpoint selection Temperature sensitivity 0 40 C 0 4 Offset 0 We...

Page 14: ...Max output current 4 kHz Irated max4 A 14 1 19 5 24 8 35 3 current for 60s 2 8 kHz Irated max8 A Motor voltage 3 VM V 0 3 Vmains 0Hz 50Hz if required up to 480Hz Power loss Operation with INx Pv W 20...

Page 15: ...3 7 3 8 kHz Irated8 A 2 4 2 4 3 9 3 9 5 5 5 5 7 3 7 3 12 kHz Irated12 A 2 0 1 9 3 3 3 0 4 6 4 3 6 1 5 7 16 kHz Irated16 A 1 8 1 7 2 9 2 7 4 1 3 8 5 5 5 1 noise optimized 4 kHz Irated4 A 2 4 2 3 3 9 3...

Page 16: ...1 6 17 6 16 5 noise optimized 4 kHz Irated4 A 9 4 8 9 13 0 12 3 16 5 15 6 23 5 22 1 noise optimized 8 kHz Irated8 A 8 0 7 6 11 1 10 5 14 1 13 3 20 0 18 8 noise optimized 12 kHz Irated12 A 7 5 7 0 10 4...

Page 17: ...ump and fan drives Type Mains input L1 L2 L3 PE motor connection U V W PE Type Operation with mains filter mains choke Fuse F1 F2 F3 E l c b Cable cross section 1 VDE UL VDE mm2 AWG 8211 M 6A B 6A 1 1...

Page 18: ...mains filter mains choke Fuse F1 F2 F3 E l c b Cable cross section 1 Fuse F1 F2 F3 E l c b Cable cross section 1 VDE UL VDE mm2 AWG VDE UL VDE mm2 AWG 8211 M 6A B 6A 1 17 M 6A B 6A 1 17 8212 M 10A B...

Page 19: ...40 series which are equipped with an analog plug in module can be used for the following process controller applications Pressure control Temperature or volume control Setpoint summation Speed or danc...

Page 20: ...dimension The controller dimensions depend on the mechanical installation see chapter 4 1 3 6 2 Analog plug in module 2 0 2 8 E 1 E 2 E 3 E 4 3 9 4 0 0 c m 4 8 0 c m 3 9 0 c m 0 1 0 V 0 2 0 m A K35 0...

Page 21: ...nstallation of filters regular cleaning etc Observe free space You can install several controllers next to each other without free space in a control cabinet Ensure unimpeded ventilation of cooling ai...

Page 22: ...he control cabinet Insert the attached fixing rail into the guides at the heat sink Horizontally with an additional fan On a pivoting frame for assembly depths 198 mm Therefore easy handling and insta...

Page 23: ...h10 135 2 3 17 63 H AM EL N c k a e d b 1 2 3 FIG 4 1 Dimensions 8211 8214 Standard assembly 1 Insert the fixing rail here for side assembly 2 Observe the free space required for the connection cable...

Page 24: ...3 K35 0148 FIG 4 2 Dimensions 8215 8218 Standard assembly 1 Insert the fixing rail here for side assembly 2 Observe the free space required for the connection cables 3 With attachable fieldbus or I O...

Page 25: ...a e b c1 2 3 c2 c3 1 1 K35 0071 FIG 4 3 Dimensions 8211 8214 DIN rail assembly 1 Assembly on two DIN rails required 2 Observe the free space required for the connection cables 3 With attachable field...

Page 26: ...ht terminal strip terminals 20 39 The unit requires 40 mm more assembly depth Step What to do 1 Remove the socket connector possibly attached to terminals 20 39 2 Connect the analog plug in terminal t...

Page 27: ...case of condensation connect the controller to the mains voltage only after the visible humidity has evaporated Please observe the restricitons of each mains type Mains Operation of the controller Not...

Page 28: ...recommend the use of screened motor cables only 8211 8214 On the front FAST ON connector 8215 8218 On the front metall surface Connect the motor cables to the screw terminals U V W anschlie en Observ...

Page 29: ...to calculate the resulting cable length lres UHV 6XP RII DOO PRWRU FDEOH OHQJWKV 1R RI PRWRU FDEOHV The components stated in the table see below are valid for chopper frequenquies 8 kHz C018 0 1 When...

Page 30: ...ke 2 3 sine filter 2 3 4 2 3 motor filter motor choke 2 3 sine filter 2 3 4 2 3 motor filter motor choke 2 3 sine filter 8213 8214 8215 8216 2 3 4 2 3 motor filter motor choke 2 3 sine filter 8215 821...

Page 31: ...F1 F3 Fuses K1 Mains contactor Z1 Mains filter mains choke see Accessories Z2 Motor filter sine filter see Accessories Z3 Brake chopper brake module see Accessories RB Brake resistor see Accessories J...

Page 32: ...he front FAST ON connector 8215 8218 On the front metal surface screw length max 12 mm If the control cables are interrupted terminal strips relays the screens must be reconnected over the shortest po...

Page 33: ...A Resolution 820X 8 bit 821X 822X 824X 10 bit Resolution 8 bit Resolution 10 bit Digital inputs 20 Voltage supply for digital inputs 820X 12 V 20 mA 821X 822X 824X 15 V 20 mA 12 V 20 mA 15 V 20 mA 28...

Page 34: ...rol connections Supply with internal control voltage 62 7 8 9 K11 K12 K14 3k 3k 3k 3k 3k Vcc GND 2 GND 1 5 2V Vref 3k3 100k 12 30V 82XX R 1k 20 28 E1 E2 E3 E4 39 PE K1 K35 0077 4 FIG 4 8 Control conne...

Page 35: ...821X 20 28 E1 E2 E3 E4 39 8279 12 30V GND1 GND2 VCC15 5 GND 0 10V R Danger There is no mains isolation between external supply and unit mass There is no double mains isolation between the mains and th...

Page 36: ...ounting plates with conductive surfaces zinc coated stainless steel allow permanent contact Varnished boards should not be used for installation in accordance with EMC If you use several mounting plat...

Page 37: ...or cable directly to the mounting plate at the brake chopper and the brake resistor with as large a surface as possible Connect the screen of the cable between controller and brake chopper directly to...

Page 38: ...E S P E S P E S P E S P E S P E S P E S P E S P E S P E P E P E FIG 4 11 Example for an installation in accordance with the EMC regulations F1 Fuse K10 Mains contactor Z1 Mains filter A or B see Acces...

Page 39: ...r check the wiring for completeness short circuit and earth fault Power connection Via L1 L2 and L3 Alternatively via terminals UG UG DC group drive Control terminals Reference potential for the contr...

Page 40: ...code table chapter 7 2 Terminal configuration C007 0 E4 E3 E2 E1 CW CCW DC brake JOG1 2 See code table chapter Machine data Chapter 5 3 ff Speed range Min field frequency C010 0 00 Hz Chapter 5 3 1 S...

Page 41: ...chronous motor speed min 1 fdmax Max field frequency Hz p Number of pole pairs Example 4 pole asynchronous motor p 2 fdmax 50 Hz nrsyn 50 60 2 1500min 1 Important With the setting of fdmin fdmax the f...

Page 42: ...rom 0 Hz to the max field frequency set under C011 Calculate the times Tir and Tif which must be set under C012 and C013 tir and tif are the times required for the change between fd1 and fd2 7LU WLU I...

Page 43: ...t reaching Imax of the controller Drive characteristic when reaching the limit value During acceleration Expansion of the acceleration ramp During deceleration Expansion of the deceleration ramp When...

Page 44: ...e characteristic V fd 2 with constant Vmin boost 4 Motor current control Control modes of the voltage characteristic Function Under C014 you can set the control mode and the voltage characteristic The...

Page 45: ...2 High dynamic positioning and feed drives 2 2 Lifts and hoists 4 2 4 2 Pumps and fan drives 3 2 3 2 Three phase reluctance motors 2 2 Three phase sliding rotor motors 2 2 Three phase motors with assi...

Page 46: ...e V f rated frequency determines the slope of the V f characteristic and has considerable influence on the current torque and power performance of the motor An internal mains voltage compensation comp...

Page 47: ...kW fd 2 Hz B Increase Vmin until you reach the following motor current Motor in short term operation at 0Hz fd 25Hz with self ventilated motors Imotor Irated motor with forced ventilated motors Imoto...

Page 48: ...tects all further motor data The following drives can be optimized by entering the nameplate data rated motor current and cos j under C088 or C091 Motor one power class smaller than the motor assigned...

Page 49: ...tting Change C021 under constant load until the speed is near the synchronous speed If C021 is set to too high values the drive may become instable overcompensation Important The change from V f chara...

Page 50: ...e In addition the influence of the PID controller can be set under C074 Under C238 you can select whether you want a setpoint precontrol or not This is very advantageous for applications in which the...

Page 51: ...parameters C010 C011 C017 C019 C037 C038 C039 C046 C049 C050 C051 and C181 to an application datum to be controlled e g speed The codes display the absolute value of an application datum Adjustment Th...

Page 52: ...Commissioning 5 14 821XKlimaBA0399 Show Hide Bookmarks...

Page 53: ...ent Heat exchanger Hot water Cold water Water injection Speed set value 8210 20 40 with operating unit Unit 1 Unit 2 DDC Speed set value K35 82K001 FIG 5 1 Application example of an air conditioning s...

Page 54: ...C2005 Configuration 0 0 Operation with open loop control via terminal 8 C008 C2008 Function relay K1 1 14 Apparent motor current C054 Current threshold C156 and acceleration finished Belt monitoring C...

Page 55: ...1BB C005 Configuration 0 0 Operation with open loop control via terminal 8 C014 Operating mode 0 3 Square characteristic V fd 2 with constant Vmin boost According to the information given in both tabl...

Page 56: ...e e g PLC Display with analog input Act pressure value Pressure sensor 0 10 V 0 4 20 m FIG 5 2 Application of a pump with pressure control Z1 Mains filter required for radio interference level A or B...

Page 57: ...Electrical controller inhibit Code settings Code Name Possible settings IMPORTANT Code Name Lenze Selection Info IMPORTANT C001 Operating mode 0 3 Setpoint selection via LECOM C005 Configuration 0 7 O...

Page 58: ...pump with level control Z1 Mains filter required for radio interference level A or B Z2 Motor filter required for motor cables screened as from 50 m unscreened as from 100 m Sine filter required for...

Page 59: ...PORTANT Code Name Lenze Selection IMPORTANT C005 Configuration 0 6 Operation with closed loop control setpoint via terminal 8 with digital frequency feedback via terminal E1 C070 PID controller gain 1...

Page 60: ...gital inputs LECOM 0 Digital inputs 1 Direction of rotation 1 1 unipolar fdmin fdmax Analog setpoint 1 1 C010 C034 C038 C039 C046 fdmax fdmax C037 fdmax fdmax Stop LU OU Output frequency Ctrl enable R...

Page 61: ...Gain Gain Master current 0 20 mA 4 20 mA inverse set value Analog set value unipolar fdmin fdmax Skip frequencies Keypad LECOM Motor potentiometer function Speed limitation with torque control C005 5...

Page 62: ...Commissioning 5 24 821XKlimaBA0399 Show Hide Bookmarks...

Page 63: ...For instance longer DC braking operations Longer operation of self ventilated motors at low speed The controllers generate an output frequency of up to 480 Hz when setting it correspondingly If an in...

Page 64: ...During operation 6 2 821XKlimaBA0399 Show Hide Bookmarks...

Page 65: ...with a C They are listed in the code table Each code provides parameters which can be used to adjust and optimize your drive The configuration of the controller can be entered by means of the keypad...

Page 66: ...rameter value of the code will be accepted after pressing SH PRG C002 The parameter value of the code will be accepted after pressing SH PRG but only if the controller is inhibited Name 820X Name of t...

Page 67: ...with factory setting 2 Overwrite PAR2 with factory setting 3 Overwrite PAR1 and PAR2 with the data of the operating module 4 Overwrite PAR1 with the data of the operating module 5 Overwrite PAR2 with...

Page 68: ...input E1 6 Operation with closed loop control setpoint via terminal 8 with digital frequency feedback via terminal E1 7 Operation with closed loop control setpoint via frequency input E1 with analog f...

Page 69: ...ke QSP I OFF D F 32 Trip set QSP I OFF D F 33 QSP PAR I OFF D F 34 CW QSP CCW QSP I OFF D F 35 JOG1 2 3 PAR D F 36 DC brake QSP PAR D F 37 JOG1 QSP PAR D F 38 JOG1 PAR Trip set D F 39 JOG1 2 3 Trip se...

Page 70: ...nd input of ramp function generator output of ramp function generator 822X 824X 15 Warning motor phase failure 16 fd C050 fdmin C010 C009 Device address 1 1 1 99 Only for LECOM applications C010 Minim...

Page 71: ...023 Imax limit generator mode 80 30 1 150 The current limit controller for operation in generator mode is not active at 30 C026 Offset adjustment analog input 0 00 10 00 0 01 V 10 00 C027 Scaling fact...

Page 72: ...ad Only display C061 Heat sink temperature Only display C070 Gain PID controller 1 00 0 00 0 01 300 00 0 0 P compone nt inactive C071 Integral action time PID controller 100 10ms 9999s 9999s I compo n...

Page 73: ...fdmax C011 8 Actual PID controller value Selection 9 25 corresponds to the relay output functions C008 and C117 LOW 0 V HIGH 10 V 9 Ready for operation 10 TRIP fault message 11 Motor is running 12 Mo...

Page 74: ...0 0 0 1 2 0 0 1 0 3 0 0 1 1 4 0 1 0 0 5 0 1 0 1 6 0 1 1 0 7 0 1 1 1 8 1 0 0 0 9 1 0 0 1 10 1 0 1 0 11 1 0 1 1 12 1 1 0 0 13 1 1 0 1 14 1 1 1 0 15 1 1 1 1 0 Function Ex depends on C001 1 Function Ex is...

Page 75: ...atic start inhibited flying restart circuit not active 1 Automatic start if term 28 HIGH flying restart circuit not active 2 Automatic start inhibited flying restart circuit active 3 Automatic start i...

Page 76: ...control 1 With setpoint precontrol C239 Frequency setting range 0 0 Bipolar 1 Unipolar C304 Password1 C305 Password2 C306 Contents of the address Should only be changed by the C307 Address changed by...

Page 77: ...ction 822X 824X 0 0 Inactive 1 TRIP 2 Warning C599 Current limit value motor phase failure detection 822X 824X 5 1 1 50 C625 Frequency 1 480 00 0 00 0 02 Hz 480 00 C626 Frequency 2 480 00 0 00 0 02 Hz...

Page 78: ...Configuration 7 14 821XKlimaBA0399 Show Hide Bookmarks...

Page 79: ...out operating module two LED at the unit front indicate the operating status LED Operating status green red Operating status on off Controller enabled on on Mains switched on automatic start inhibited...

Page 80: ...tory buffer is used to trace faults The fault messages are stored in the history buffer in the order of their occurrence The memory locations can be retrieved via the codes Structure of the history bu...

Page 81: ...eleration processes with overcurrent Check drive dimensioning OC6 Overload motor Motor is thermally overloaded for instance because of impermissible continuous current Check drive selection frequent o...

Page 82: ...y necessary to repeat the data transfer or load the factory setting before enabling the controller Pr1 Faulty PAR1 transfer via the operating module PAR1 is defective before enabling the controller Pr...

Page 83: ...P reset selection 0 TRIP reset by pressing the STP key or a LOWsignal at ctrl enable 1 Auto TRIP reset C171 Delay for Auto TRIP Reset 0 00 0 00 0 01s 60 00 Function You can select whether the fault is...

Page 84: ...Troubleshooting and fault elimination 8 6 821XKlimaBA0399 Show Hide Bookmarks...

Page 85: ...dule EMF2102IB V001 RS485 fieldbus module EMF2102IB V002 Level converter for RS485 EMF2101IB PC system cable RS232 485 EWL0020 Optical fibre fieldbus module EMF2102IB V003 Optical fibre adaptor for PL...

Page 86: ...ZF3 008A003 EZF3 008A003 EZF3 016A003 Operation without mains choke EZF3 008A003 EZF3 008A003 EZF3 008A003 inadmissible Motor filter ELM3 030H004 ELM3 030H004 ELM3 014H010 ELM3 014H010 Sine filter EZS...

Page 87: ...ration without mains choke EZF3 016A003 EZF3 024A001 EZF3 024A001 inadmissible Motor filter ELM3 014H010 ELM3 007H025 ELM3 007H025 ELM3 007H025 Sine filter EZS3 009A002 EZS3 013A001 EZS3 017A001 EZS3...

Page 88: ...Accessories 9 4 821XKlimaBA0399 Show Hide Bookmarks...

Page 89: ...field frequency 5 3 Connection Analog plug in module 4 15 Control Connection diagram 4 14 Control cables 4 12 Mains 4 8 Motor 4 8 Power Circuit diagram 4 11 Connection diagram Control connections 4 14...

Page 90: ...reening 4 17 Electrical 4 7 Mechanical 4 1 Installation height 2 1 Insulation strength 2 1 J Jumper Analog setpoint selection 4 13 L Labelling Controller 1 2 LED 8 1 Legal regulations 1 2 Liability 1...

Page 91: ...to persons 2 3 Scope of delivery 1 1 Screening EMC 4 17 Motor cable 4 8 Short set up 5 2 Signal flow charts 5 22 Switch on Initial 5 1 Switch on sequence Factory setting 5 2 T Technical data 2 1 Analo...

Page 92: ...Index 10 4 821XKlimaBA0399 Show Hide Bookmarks...

Page 93: ...Index 821XKlimaBA0399 10 5 Show Hide Bookmarks...

Page 94: ...Index 10 6 821XKlimaBA0399 Show Hide Bookmarks...