Electrical installation
Devices in the power range 0.37 ... 22 kW (3/PE AC 400 V)
Terminal assignment of the power connections
l
118
EDS84ASC552 EN 6.0
Motor connection
Terminal X105
Labelling
Description
PE
Rb1
Rb2
V
U
W
"
PE
U, V, W
Motor
PE
PE conductor
"
Functional earth
HF−shield termination by connection to PE
8400GGXx002b
Terminal data
PE
Conductor
cross−section
Tightening
torque
!
Conductor
cross−section
Tightening
torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
[mm
2
]
[AWG]
[Nm]
[lb−in]
E84AVxxx3714
E84AVxxx5514
E84AVxxx7514
E84AVxxx1124
E84AVxxx1524
E84AVxxx2224
1 ... 2.5
18 ... 12
0.5
4.4
3.5 x 0.6
1 ... 6
18 ... 10
1.7
15
PZ 2
7 x 1
E84AVxxx3024
E84AVxxx4024
E84AVxxx5524
1 ... 6
18 ... 10
0.5
4.4
3.5 x 0.6
2.5 ... 16
12 ... 6
3.4
30
PZ 2
7 x 1
E84AVxxx7524
E84AVxxx1134
E84AVxxx1534
1 ... 16
18 ... 6
1.2
10.6
5.5 x 1
2.5 ... 16
12 ... 6
3.4
30
PZ 2
7 x 1
E84AVxxx1834
E84AVxxx2234
1.5 ... 25
16 ... 2
3.5
31
6.5 x 1
2.5 ... 25
12 ... 2
4.0
35
PZ 2
7 x 1