Electrical installation
StateLine C control terminals
Digital inputs and outputs
l
132
EDS84ASC552 EN 6.0
Example circuit
0
1
E84AVSC...
24 V
int.
24E
DI1
DI2
DI3
DI4
RFR
DC 24 V
(+19.2 … +28.8 V)
S1
3.3k
3.3k
3.3k
3.3k
3.3k
X4
GND-IO
DO1
GIO
24I
GND-IO
E84AVSC...
24 V
int.
24E
DI1
DI2
DI3
DI4
RFR
S1
3.3k
3.3k
3.3k
3.3k
3.3k
X4
GND-IO
DO1
GIO
24I
GND-IO
8400SLC015
8400SLC016
2
3
DC 24 V
(+19.2 … +28.8 V)
E84AVSC...
24 V
int.
24E
DI1
DI2
DI3
DI4
RFR
S1
3.3k
3.3k
3.3k
3.3k
3.3k
X4
GND-IO
DO1
GIO
24I
GND-IO
DC 24 V
(+19.2 … +28.8 V)
S1
"
E84AVSC...
24 V
int.
24E
DI1
DI2
DI3
DI4
RFR
3.3k
3.3k
3.3k
3.3k
3.3k
X4
GND-IO
DO1
GIO
24I
GND-IO
8400SLC017
8400xLC022
Fig. 6−28
Wiring examples of the digital inputs and outputs
0
Wiring with one (or several) digital input (here: DI1), e.g. a PLC; optional: external
24 V supply
1
Digital control (relay, valve, ...) with internal 24 V supply
2
Digital control (relay, valve, ...) with external 24 V supply
3
Connection of an HTL incremental encoder with a maximum input frequency of
10 kHz
DI1
track A
DI2
track B
RFR
Input for controller enable; wiring is always required.
GIO
GND−IO
Ground reference potential for the digital inputs and outputs
X4
Terminal for the digital inputs and outputs
efesotomasyon.com - Lenze