Electrical installation
HighLine C control terminals
Digital inputs and outputs
l
137
EDS84ASC552 EN 6.0
6.7.3
Digital inputs and outputs
X5
24 V int.
50
mA
24E
DI1
DI2
DI3
DI4
RFR
DC 24 V
(+19.2...
+28.8 V)
S1
2.7k
2.7k
3.3k
3.3k
3.3k
X5
GND-I
DI5
DI6
DI7
GI
24I
1.6k
1.6k
3.3k
8400HLC036
8400HLC045
Fig. 6−33
Connection of the digital inputs
Labelling
Description
RFR
Controller enable/controller inhibit, always required
DI1
Digital input 1
^
IEC61131−2, type 1 or two−track frequency input, for HTL
encoder 0 ... 100 kHz
track A
DI2
Digital input 2
track B
DI3
Digital input 3
^
IEC61131−2, type 1
DI4
Digital input 4
DI5
Digital input 5
DI6
Digital input 6
IEC61131−2, type 1 or
two−track frequency input for HTL encoder 0 ... 10 kHz
DI7
Digital input 7
GI
GND digital inputs
Terminal data
Conductor cross−section
Tightening torque
!
[mm
2
]
[AWG]
[Nm]
[lb−in]
flexible
0.2 ... 1.5
24 ... 16
−
−
2.5 x 0.4
with wire end ferrule
efesotomasyon.com - Lenze