Braking operation
Braking operation with external brake resistor
Operation at rated mains voltage 400 V
l
151
EDS84ASC552 EN 6.0
8.2.2
Operation at rated mains voltage 400 V
Switching threshold V
BRmax
: 725 V, adjustable
R
Bmin
[
]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
t
Z
[s]
t
on
[s]
t
fp
[s]
Type
E84AVxxx3714
390
1.9
1.3
1.9
1.3
−
−
E84AVxxx5514
390
1.9
1.3
1.9
1.3
−
−
E84AVxxx7514
390
1.9
1.3
1.9
1.3
−
−
E84AVxxx1124
180
4.0
2.9
4.0
2.9
−
−
E84AVxxx1524
180
4.0
2.9
4.0
2.9
−
−
E84AVxxx2224
150
4.8
3.5
4.8
3.5
−
−
E84AVxxx3024
47
15.4
11.2
13.0
9.4
−
−
E84AVxxx4024
47
15.4
11.2
13.0
9.4
−
−
E84AVxxx5524
47
15.4
11.2
13.0
9.4
−
−
E84AVxxx7524
27
26.9
19.5
26.9
19.5
−
−
E84AVxxx1134
27
26.9
19.5
26.9
19.5
−
−
E84AVxxx1534
18
40.3
29.2
40.3
29.2
−
−
E84AVxxx1834
15
48.3
35.0
48.3
35.0
−
−
E84AVxxx2234
15
48.3
35.0
48.3
35.0
−
−
R
Bmin
Minimum brake resistance, nominal value ±10 %
I
BRmax
Peak current
P
BRmax
Peak braking power
I
BRd
Continuous current RMS − important for the dimensioning of the cables
P
Bd
Continuous braking power
t
Z
Cycle time, periodic load change with running time and recovery time
t
on
Running time
t
Z
− t
on
Recovery time
t
fp
Maximum running time without initial load and compliance with the recovery
time
efesotomasyon.com - Lenze