Braking operation
Operation with spring−applied brake
Wiring
l
162
EDS84ASC552 EN 6.0
ƒ
Integrated brake control for devices in the HighLine version
L1
L2
L3
N
PE
F10
BD2
U
L1
L3
PE
L2
-
+
BD1
V
M
3~
E84AVHC...
~
24 V DC
1.5 mm²
G
B
W
24B
PE
X
107
"
"
PES
BD1 = +
BD2 = -
}
E84HLC005
E84AVHC...
Controller in the HighLine version
F10
Cable protection in secondary circuit.
For dimensioning the fuse, observe the standards of the cable protection and
the safety instructions for the installation according to UL or UR!
PES
HF−shield termination by large surface connection to PE.