Technical data
StateLine C control terminals
Analog inputs
l
55
EDS84ASC552 EN 6.0
4.6.2
Analog inputs
Labelling
Feature
Rated value
X3/A1U
Input
± 10 V
Input resistance
> 80 k
Input voltage in case of open circuit
Display "0" (U < 0.2 V, absolute)
Sampling frequency
1 kHz (1 ms)
Accuracy
0.1 V
Electric strength of external voltage
15 V, permanent
A/D converter
Resolution 10 bits + sign
Error 1 digit
0.1 % relating to the final value
X3/A1I
Input
0 ... +20 mA
Parameterisable
4 ... +20 mA, fail−safe
Input resistance
215
Input current in case of open circuit
Display "0" (I < 0.1 mA)
Sampling frequency
1 kHz (1 ms)
Accuracy
0.1 mA
Electric strength of external voltage
7 V, permanent
A/D converter
10 bit resolution
Error 1 digit
0.1 % relating to the final value
X3/GA
GND, reference potential for analog signals
4.6.3
Analog outputs
Labelling
Features
Rated value
X3/O1U
Output voltage
0 ... 10 V
Output current
2 mA
Capacitive load
max 1
F
Voltage − 0 V
Display "0" (U < 0.1 V, absolute)
Output voltage at reset
< 0.5 V
Accuracy
2 % relating to the final value
Short−circuit strength
Unlimited period
Electric strength of external voltage
Not guaranteed
X3/AR
Reference 10 V
10.5 V
Tolerance
±0.5 V
Capacitive load
max 1
F
Short−circuit strength
Unlimited period
Electric strength of external voltage
Not guaranteed
Permissible current loading
10 mA
X3/GA
GND, reference potential for analog signals