Mechanical installation
Standard devices in the power range 0.25 ... 2.2 kW
Filter mounting in "standard" technique
l
65
EDS84ASC552 EN 6.0
E84ZESR007
Fig. 5−2
Assembly with footprint filter
Proceed as follows for installation:
1. Prepare M5 threaded holes on the mounting plate and equip them with screws and
washers.
– Use four M5 screw and washer assemblies or M5 hexagon socket screws with
washers.
– Do not yet tighten the screws.
2. Mount the filter onto the prepared mounting plate.
– Only tighten the screws hand−tight.
3. Loosen the two screw and washer assemblies to fix the standard device on the filter.
– Two M5 × 14 mm screw and washer assemblies.
4. Mount the standard device onto the filter and tighten the screws.
– Observe the instructions in the documentation for the standard device.
– Tightening torque: 3.4 Nm (30 lb−in)
5. If necessary, preassemble additional units.
6. Align all units.
7. Screw all units onto the mounting plate.
– Tightening torque: 3.4 Nm (30 lb−in)
efesotomasyon.com - Lenze