Mechanical installation
Standard devices in the power range 3 ... 22 kW
Assembly without filter in "standard" technique
l
72
EDS84ASC552 EN 6.0
Assembly without filter in "standard" technique
For mounting, use two screws M5 x >10 mm. The mounting location and material must
ensure a durable mechanical connection.
ƒ
Screw and washer assemblies or hexagon socket screws with washers are
recommended.
How to proceed:
1. Prepare the fixing holes on the mounting surface.
2. Screw the controller directly to the mounting surface.
8400GG065
Fig. 5−6
Assembly without filter
a
b
c
c1
d
e
f
[kW]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[kg]
E84AVxxE3024
E84AVxxE4024
E84AVxxE5524
3 ... 5.5
140
360
199
219
285
140
120
4.4
E84AVxxE7524
E84AVxxE1134
E84AVxxE1534
7.5 ... 15
140
416
199
219
340
140
120
5.8
E84AVxxE1834
E84AVxxE2234
18.5 ... 22
205
430
250
270
340
205
180
12.0