Mechanical installation
Standard devices in the power range 3 ... 22 kW
Mounting in "cold plate" technique
l
80
EDS84ASC552 EN 6.0
Ambient conditions
ƒ
The rated data and the derating factors at increased temperature also apply to the
ambient temperature of the drive controllers.
ƒ
Temperature at the cooling plate of the drive controller: max. 75 °C.
)
Note!
ƒ
Apply heat conducting paste onto the cooler and cooling plate of the
controller before you screw the controller onto the cooler to troller on the
cooler to keep the heat transfer resistance as low as possible. For this
purpose a standard heat conducting paste can be used.
8400HLC077
Fig. 5−11
Dimensions: Assembly in "cold plate" technique for devices in the power range 3 ... 5. kW
a
b
c
c1
d
e
f
[kW]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[kg]
E84AVxxC3024
E84AVxxC4024
E84AVxxC5524
3.0 ... 5.5
174
366
141
161
300
160
15
2.7