Mechanical installation
Important notes
5
l
61
EDS84ASC552 EN 6.0
5
Mechanical installation
5.1
Important notes
{
Danger!
Sticker with warning note must be displayed prominently and close to the
device!
)
Note!
The devices must be installed in housings (e.g. control cabinets) to meet
applicable regulations.
ƒ
If the cooling air is polluted (fluff, (conductive) dust, soot, aggressive gases), take
adequate countermeasures, as e.g.:
– Separate air guide
– Installation of filters
– Regular cleaning
ƒ
Possible mounting position:
– Vertical on the mounting plate (mains connections at the top, motor connection at
the bottom)
ƒ
Maintain the specified free spaces above and below the controller to other
installations!
– Ensure unimpeded ventilation of cooling air and outlet of exhaust air.
– You can install several controllers of the 8400 L−force Inverter Drives product range
next to each other without any clearance in the control cabinet.
ƒ
The mounting plate of the control cabinet must be electrically conductive.
ƒ
In case of continuous vibrations or shocks use vibration dampers.