8400 StateLine C | Reference manual
Motor control (MCTRL)
V/f characteristic control (VFCplus)
Tip!
Cases of application for this function:
• Operation of reluctance motors or synchronous motors during controlled
acceleration (reduction of natural frequencies caused by wrong excitation).
• Adaptation of the voltage requirement for the motor, depending on specific
load conditions.
Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the
Project view
and select the 8400 StateLine controller.
2. Go to
Workspace
and change to the
Application parameters
tab.
3. Select the motor control "10: VFCplus: V/f definable" from the
Overview
dialog box
in the
Motor control
list field:
4. Click the
Motor control V/f definable
button to change to the
Overview
Motor
control V/f
dialog box.
• This dialog level only shows a simplified signal flow with the most important
parameters.
• When you click the
>>More details
button in the left-most position, a signal
flow with more details/parameters is displayed.