8400 StateLine C | Reference manual
Motor control (MCTRL)
Encoder/feedback system
218
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
4. Go to the
Overview
Motor data
dialog level and click the
Encoder/Feedback
system...
button.
Parameterisation dialog in the »Engineer«
Short overview of the relevant parameters:
General procedure
(if the encoder is connected to the digital inputs DI1 and DI2)
1. Define the function of the digital inputs DI1 and DI2 in
C00115/1
.
2. Set the encoder increments in
C00420/1
.
3. Select "1: Encoder signal FreqIn12" in
C00495/1
.
4. Adapt the filter time of the speed measurement in
C00497/1
.
Parameter
Info
Lenze setting
Value Unit
C00115/1
Fct. DI 1/2 10kHz
• Function of the digital inputs DI1 and DI2
DI1=In1 | DI2=In2
C00420/1
Encoder increments at FreqIn12
• If the digital inputs DI1 and DI2 are used as
encoder inputs.
128 Inc/U
C00425/1
Encoder scanning time FreqIn12
• If the digital inputs DI1 and DI2 are used as
encoder inputs.
10 ms
C00495
Speed sensor selection
• Source of feedback signal for speed control.
No sensor
C00496
Encoder evaluation method (
220)
Combined encoder method
C00497/1
Encoder filter time FreqIn12
• If the digital inputs DI1 and DI2 are used as
encoder inputs.
1.0 ms
C00586
Resp. to encoder open circuit
Encoder open-circuit monitoring (
244)
Fault
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com