8400 StateLine C | Reference manual
I/O terminals
Digital terminals
Parameter
Function at constant input value
Selection:
C02844/1
= "0: Loading with level" or "1: Loading with edge"
[6-2]
Switching performance if the overflow is in the positive direction
If "0: Loading with level" is selected in
C02844/1
, the
bPosIn12_Load
input is status-
controlled: In case of a TRUE signal, the integrator is loaded with the value at
dnPosIn12_Set_p
and the
bPosIn12_State
output is set to FALSE.
If "1: Loading with edge" is selected in
C02844/1
, the
bPosIn12_Load
input is edge-
controlled: In case of a FALSE/TRUE edge, the integrator is loaded with the value at
dnPosIn12_Set_p
and then immediately continues to integrate, the
bPosIn12_State
output is set to FALSE.
A positive
nFreqIn12_v
signal is incremented (the counter content is increased with
every cycle).
A negative
nFreqIn12_v
signal is decremented (the counter content is reduced with
every cycle).
Parameter
Possible settings
Info
C02844/1
Function
0 Loading with level
Load integrator with TRUE level at
the
bPosIn12_Load
input (Lenze
setting).
1 Loading with edge
Load integrator with FALSE/TRUE
edge at the
bPosIn12_Load
input.
2 Loading with level + reset
Load integrator when reaching the
comparison value or with TRUE level
at the
bPosIn12_Load
input.
C02845
0
2000000000 Comparison value
• Is valid for both the positive and
the negative value range.
• Lenze setting: 0
n
Overflow at ±2147483648 incr. (±32767 encoder revolutions)
o
C02845
: Comparison value (applies to both positive and negative value range)
dnPosIn12_p
t
0
TRUE
FALSE
bPosIn12_State