User-defined terminal assignment
In order to individually adapt the preconfigured assignment of the input/output terminals
to your application, you can choose one of the following procedures:
A. In the »Engineer«:
– Change the terminal assignment on the
Terminal assignment
tab.
– Change the signal assignment on the
Application Parameters
tab, on the dialog level
Overview
Signal flow
.
– Change the interconnections in the FB editor (on the I/O level).
B. In the »Engineer« or with the keypad:
– Change the parameters for signal configuration in the parameters list.
Tip!
First of all, select a Lenze configuration useful for the purpose at hand by going to
C00005
and selecting a technology application that matches your drive task and
then going to
C00007
and selecting an appropriate control mode. You will then
have an application for which there is a signal flow, logical block links and terminal
assignment.
We recommend using the »Engineer« for the implementation of comprehensive
user-defined drive solutions.
Note!
If you change the preconfigured assignment of the input/output terminals, the
terminal assignment will be a user-defined one. In
C00007
, control mode "0:
Interconnection changed" will be shown.