8400 StateLine C | Reference manual
I/O terminals
User-defined terminal assignment
284
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
6.4.2
Changing the terminal assignment with the keypad
You can reconfigure the preconfigured terminal assignment with the keypad (and with the
»Engineer«) by means of so-called configuration parameters.
Each configuration parameter represents a signal input of a system block or application
block.
Each configuration parameter contains a selection list with output signals of the same
type of data.
Logical linking is thus carried out by selecting the output signal for the corresponding
signal input.
In the following example, digital output 1 (
LS_DigitalOutput
.bOut1
input) is logically
linked to the status signal "Drive ready" (
LA_nCtrl_bDriveReady
output signal):
Configuration parameters for the analog and digital output terminals
The preconfigured assignment of the analog and digital output terminals can be altered by
means of the subcodes of
C00620
and
C00621
:
Other subcodes (not shown here) allow the configuration of input signals of different
system blocks and port blocks.
Parameter
Info
Lenze setting
Value Unit
Analog outputs - terminal assignment
C00620/1
LS_AnalogOutput: nOut1_a
1003: LA_nCtrl_nMotorSpeedAct_a
Digital outputs - terminal assignment
C00621/1
LS_DigitalOutput:bRelay
1001: LA_nCtrl_bDriveFail
C00621/2
LS_DigitalOutput:bOut1
1000: LA_nCtrl_bDriveReady