Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
305
8400 StateLine C | Reference manual
Technology applications
TA "Actuating drive speed"
7.2.3.3
Terminals 11
Connection
Assignment
Connection
Assignment
X101/NC-NO
LA_NCtrl.bDriveFail
X4/RFR
LA_NCtrl.bFailReset
X3/A1U
LA_NCtrl.nMainSetValue_a *
X4/DI1
LA_NCtrl.bSetSpeedCcw
X3/A1I
-
X4/DI2
LA_NCtrl.bSetDCBrake
X3/O1U
LA_NCtrl.nMotorSpeedAct_a *
X4/DI3
LA_NCtrl.bMPotUp
* 10 V
≡
100 % reference speed (
C00011
)
X4/DI4
LA_NCtrl.bMPotDown
X4/DO1
LA_NCtrl.bDriveReady
+
=
+
X4
DI3
DI2
DI4
GIO
24I
DI1
RFR
24E
+
X3
AR
A1U
GA
A1I
DO1
O1U
COM
NC
NO
X101
CG
C
L
CH
X1
Controller enable / reset error
Change of direction of rotation
DC brake active
Speed higher
Speed lower
Motor potentiometer
External
supply
24 V DC
DriveReady
Speed setpoint
Actual speed value
DriveFail