Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
307
8400 StateLine C | Reference manual
Technology applications
TA "Actuating drive speed"
7.2.3.5
Keypad
Connection
Assignment
Connection
Assignment
X101/NC-NO
LA_NCtrl.bDriveFail
X4/RFR
LA_NCtrl.bFailReset
X3/A1U
-
X4/DI1
-
X3/A1I
-
X4/DI2
-
X3/O1U
LA_NCtrl.nMotorSpeedAct_a *
X4/DI3
-
* 10 V
≡
100 % reference speed (
C00011
)
X4/DI4
-
X4/DO1
LA_NCtrl.bDriveReady
Quick commissioning
SAVE
Par1 Quick commissioning
Terminals
Keypad
SAVE
Par1 8400 StateLineC
User - Menu
Logbook
Go to param
Quick commissioning
C2/1
C7
C728
C11
C12
C13
C15
C16
C22
C87
C89
C39/1
C727/3
C727/4
C51
C54
+
=
+
+
X4
DI3
DI2
DI4
GIO
24I
DI1
RFR
24E
+
X3
AR
A1U
GA
A1I
DO1
O1U
COM
NC
NO
X101
CG
C
L
CH
X1
Controller enable /
reset error
External
supply
24 V DC
Engineer:
Keypad:
All parameters
Quick commissioning
Terminal
Keypad
DriveReady
Actual speed value
DriveFail
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com