8400 StateLine C | Reference manual
Technology applications
TA "Switch-off positioning"
328
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
7.3.2.1
Truth table for activating the pre-switch off
[7-1]
Truth table for activating the pre-switch off
Input
Function
Response in the setpoint generator
(FB L_NSet)
bJogCtrl
InputSel1
bJogCtrl
InputSel2
FALSE
FALSE
Pre-switch off inactive
No response
• The input signal
bJogCtrlRfgIn
is output
directly at output
bRfgOut
.
• The input signals
bJogCtrlJog1
and
bJogCtrlJog2
are passed through 1:1 to
the downstream FB
L_NSet
for the
selection of fixed setpoints.
TRUE
FALSE
The
bJogCtrlSlowDown1
and
bJogCtrlStop1
inputs are evaluated.
Pre-switch off can be activated
• If the slowdown function is activated via
the selected
bJogCtrlSlowDown
input,
fixed setpoint 2 is activated in the
setpoint generator.
• If the stop function is activated via the
selected
bJogCtrlStop
input, the setpoint
generator is deactivated.
FALSE
TRUE
The
bJogCtrlSlowDown2
and
bJogCtrlStop2
inputs are evaluated.
TRUE
TRUE
The inputs
bSJogCtrllowDown3
and
bJogCtrlStop3
are evaluated.