8400 StateLine C | Reference manual
Technology applications
TA "Switch-off positioning"
338
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
7.3.4
Process data assignment for fieldbus communication
The fieldbus communication is connected (preconfigured) to the previously selected
technology application by selecting the corresponding control mode in
C00007
:
"30:
CAN
" for the connection to the system bus (CAN)
"40:
MCI
" for the connection to a plugged-on communication module (e.g. PROFIBUS)
The assignment of the process data words does not depend on the applied bus system but
exclusively on the application:
Input words
Name
Assignment
Word 1 DriveControl
Control word
• See table below for bit assignment.
Word 2 MainSetValue
Speed setpoint
• Scaling: 16384
≡
100 % reference speed (
C00011
)
Word 3 -
Not preconfigured
Word 4 -
Not preconfigured
Word 5 ... 16 -
Not preconfigured
• Only available for control mode "40: MCI".
Control word
Name
Function
Bit 0 SwitchOn
1
≡
Change to the "
SwitchedOn
" device status
• This bit must be set in the CAN/MCI control word to ensure
that the device changes to the "
SwitchedOn
" device status
after mains connection without the need for a master control
specifying this bit via fieldbus.
• If control via a bus system is not wanted (e.g. in the case of
control via terminals), the
wDriveCtrl
output signal of the
LS_ParFix
system block can be connected to the control word
inputs.
Bit 1 DisableVoltage
1
≡
Inhibit inverter control (IMP - pulse inhibit)
Bit 2 SetQuickStop
1
≡
Activate quick stop (QSP).
Activate/Deactivate quick stop (
83)
Bit 3 EnableOperation
1
≡
Enable controller (RFR)
• If control via terminals is performed, this bit must be set both
in the CAN control word and in the MCI control word.
Otherwise, the controller is inhibited.
Enable/Inhibit controller (
82)
Bit 4 ModeSpecific_1
Reserved (currently not assigned)
Bit 5 JogCtrlInputSel1
Binary coded selection of the switch-off position 1 ... 3
• Activation of the signal pairs
bJogCtrlSlowDown1/bJogCtrlStop1
,
bJogCtrlSlowDown2/bJogCtrlStop2
or
bJogCtrlSlowDown3/bJogCtrlStop3
according to the
Truth
table for activating the pre-switch off
.
Bit 6 JogCtrlInputSel2
Bit 7 ResetFault
1
≡
Reset fault (trip reset)
• Acknowledge fault message (if the error cause has been
eliminated).
Reset error (
84)
Bit 8 bJogCtrlRfgIn
Ramping down of the setpoint generator in the
downstream
L_NSet
FB according to the
Truth table for
activating the pre-switch off
Bit 9 reserved_1
Reserved (currently not assigned)
Bit 10 reserved_2