8400 StateLine C | Reference manual
Basic drive functions (MCK)
Speed follower
360
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
8.3
Speed follower
The 8400 StateLine controller only supports the "Speed follower" operating mode, in which
the drive follows a speed setpoint.
8.3.1
Parameter setting
Short overview of parameters for the "speed follower" operating mode:
In the »Engineer», you can set the initial limit by means of the dialog box
Min/Max speed
.
Open the
Min/max speed
dialog box by opening the
Application Parameters
tab and
clicking on the following button on the dialog level
Overview
Signal flow
:
Parameter
Info
Lenze setting
Value Unit
C02610/2
MCK: Ramp time synchr. setpoint
2.000 s
C02611/1
MCK: Pos. max. speed
199.99 %
C02611/2
MCK: Pos. min. speed
0.00 %
C02611/3
MCK: Neg. min. speed
0.00 %
C02611/4
MCK: Neg. max. speed
199.99 %
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com