Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
365
8400 StateLine C | Reference manual
Basic drive functions (MCK)
Holding brake control
Short overview of parameters for holding brake control:
Parameter
Info
Lenze setting
Value Unit
C02580
Holding brake: Operating mode
0: Brake control off
C02581/1
Holding brake: Switching threshold
5.00 %
C02581/2
Holding brake: Hyst. release
1.00 %
C02581/3
Holding brake: Hyst. close
1.00 %
C02581/4
Holding brake: FF control starting value 1
0 %
C02581/5
Holding brake: FF control starting value 2
0 %
C02582
Holding brake: Setting
0
C02589/1
Holding brake: Closing time
100 ms
C02589/2
Holding brake: Release time
100 ms
C02589/3
Holding brake: Waiting time status
100 ms
C02589/4
Holding brake: Ramp FF control
0 ms
C02593/1
Holding brake: Actual value monitoring
0.000 ms
C02593/2
Holding brake: Application delay
0.000 ms
C02610/1
MCK: Holding brake ramp time synchr.
2.000 s
C02607
Holding brake: Status
-
C00830/68
MCK: nMBrakeAddValue_a
- %
C00833/80
MCK: bMBrakeRelease
-
C00833/81
MCK: bMBrakeStartValue2
-
C00833/82
MCK: bMBrakeApplied
-
Highlighted in grey = display parameter