Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
389
8400 StateLine C | Reference manual
Diagnostics & error management
Logbook
9.5
Logbook
The integrated logbook function of the controller chronologically logs important events
within the system and plays an important role for troubleshooting and controller
diagnostics.
Events that can be logged
The following events can be logged in the logbook:
Error messages of the operating system
(
401)
Error messages generated by the application (via
LS_SetError
)
Loading/saving of parameter sets, loading of the Lenze setting
(in preparation)
Transmitting the firmware to the controller
(in preparation)
Switching on/off of the controller
Information saved
For each event, the following information is saved in the logbook:
Type of response to the event (e.g. fault, warning or information)
Subject area that activated the event (e.g. CAN or USER).
Event
Value of power-on time meter
Selected process values (analog % signals, binary signals)
Memory depth
Maximum number of logbook entries: 14
(extension in preparation)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com