Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
503
8400 StateLine C | Reference manual
Fieldbus interface
Control mode "MCI"
11.2
Control mode "MCI"
"40: MCI" can be selected as a control mode in
C00007
in order to quickly and easily set-up
drive controller control by means of MCI-PDOs via the fieldbus interface.
Given that the technology applications are fundamentally different and have different
requirements regarding the signals sent to them, predefined assignment of the MCI-PDOs
depends on the technology application selected in
C00005
:
TA "Actuating drive speed":
Process data assignment for fieldbus communication
(
311)
TA "Switch-off positioning":
Process data assignment for fieldbus communication
(
338)
Tip!
The predefined assignment of the MCI-PDOs can be parameterised by means of
PDO mapping and can be freely configured on the I/O level in the function block
editor (FB editor).