8400 StateLine C | Reference manual
Parameter reference
Structure of the parameter descriptions
522
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
14.1.3.4
Parameters with subcodes
Description structure
Parameter setting in the »Engineer«
The »Engineer« parameter list displays each subcode individually. The parameters are set
as described in the previous chapters.
14.1.4
Parameter attributes
The table footers contain the parameter attributes:
Parameter | Name:
Cxxxxx | _____________
Data type: _______
Index: _______
Description
Setting range
(min. value | unit | max. value)
Subcodes
Lenze setting
Cxxxxx/1
Cxxxxx/2
Cxxxxx/3
Cxxxxx/4
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Attribute
Meaning
;
Read access
Read access to parameter possible.
;
Write access
Write access to parameter possible.
• Please also observe the following attributes:
;
CINH
Parameter value can only be changed when the controller is
inhibited.
;
PLC STOP
Parameter value can only be changed when the application is
stopped.
;
No transfer
Parameter is
not
transferred to controller when the command Download parameter set is
executed.
;
COM
Communication-relevant parameter
• This parameter is relevant for parameter data transfer via the (CAN) system bus.
;
MOT
Motor control parameters