8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00055
538
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C00055
C00056
C00057
C00058
C00059
Parameter | Name:
C00055 | Actual values
Data type: INTEGER_16
Index: 24520
d
= 5FC8
h
Note:
When a single-track feedback has been selected for the HTL encoder (
C00115
= 1 or 3), the sign of the actual speed
value is created from the sign of the speed setpoint. In C00055/1, always a positive speed is displayed.
Display range
(min. value | unit | max. value)
-32767
rpm
32767
Subcodes
Info
C00055/1
Actual value - HTL encoder FreqIn12
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00056 | Torque
Data type: INTEGER_32
Index: 24519
d
= 5FC7
h
Display of the current torque
Display range
(min. value | unit | max. value)
-65000.00
Nm
65000.00
Subcodes
Info
C00056/1
Torque setpoint
• Only in case of sensorless vector control (
SLVC
).
C00056/2
Actual torque value
• Estimated actual torque for all motor control modes.
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00057 | Maximum torque
Data type: UNSIGNED_32
Index: 24518
d
= 5FC6
h
Display of the maximum torque to be generated by the motor
• The maximum torque to be generated by the motor depends on various factors, e.g. on Imax in motor mode
(
C00022
) and the motor type used.
Display range
(min. value | unit | max. value)
0.00
Nm
65000.00
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00058 | Output frequency
Data type: INTEGER_32
Index: 24517
d
= 5FC5
h
Display of the current output frequency
Display range
(min. value | unit | max. value)
-1300.00
Hz
1300.00
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00059 | Appl.: Reference frequency C11
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display of the field frequency which corresponds to the reference speed set in
C00011
.
Display range
(min. value | unit | max. value)
0.00
Hz
1300.00
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com