Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
547
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00114
C00114
C00115
Parameter | Name:
C00114 | DigInX: Inversion
Data type: UNSIGNED_16
Index: 24461
d
= 5F8D
h
The polarity of each digital input of the device can be inverted via this bit field.
Digital terminals
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF
0x0000
(decimal: 0)
Value is bit-coded: (
;
= bit set)
Info
Bit 0
DI1 inverted
Inversion of digital input 1
Bit 1
DI2 inverted
Inversion of digital input 2
Bit 2
DI3 inverted
Inversion of digital input 3
Bit 3
DI4 inverted
Inversion of digital input 4
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved
Bit 8
Reserved
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
RFR inverted
Inversion of digital input RFR (controller enable)
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00115 | DI1| DI2: Function
Data type: UNSIGNED_8
Index: 24460
d
= 5F8C
h
Function assignment of the digital terminals DI1 and DI2
Digital terminals
:
Function assignment
Selection list
Info
0 DI1=In1 | DI2=In2
DI1 = digital input
DI2 = digital input
1 DI1=FreqIn12 | DI2=In2
DI1 = 1-track frequency input
DI2 = digital input
2 (DI1/DI2)=FreqIn12 (2-track)
DI1 and DI2 = 2-track frequency input
3 ( DI1/DI2=+- ) = FreqIn12
DI1 = 1-track frequency input
DI2 = direction
4 DI1=CountIn1 | DI2=In2
DI1 = counter input
DI2 = digital input
Subcodes
Lenze setting
Info
C00115/1
0: DI1=In1 | DI2=In2
Function assignment of DI1 and DI2
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com