8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00164
560
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C00164
86 MCI word2 input bit15
87 Position controller: Limit
88 Speed controller: Limit
89 Speed setpoint: Limit
90 Torque setpoint: Limit
91 Current setpoint: Limit
92 DC injection brake active
93 Quick stop is active
94 Pulse inhibit is active
95 Controller inhibit is active
96 Safe status active
97 Direction of rotation ccw
98 Actual speed = 0
99 L_Or_1: Out
100 L_DFlipFlop_1: Out
101 L_DigitalDelay_1: Out
102 L_Compare_1: Out
103 L_Compare_2: Out
104 L_NSet_1: Setpoint reached
105 L_DigitalLogic_1: Out
106 L_SignalMonitor_b: Out1
107 L_SignalMonitor_b: Out2
108 L_SignalMonitor_b: Out3
109 L_SignalMonitor_b: Out4
110 L_PCTRL_1: act=set
Subcodes
Lenze setting
Info
C00163/1
0: No signal
Logbook - binary element 1
C00163/2
0: No signal
Logbook - binary element 2
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00163 | Logbook - binary elements
Data type: UNSIGNED_16
Index: 24412
d
= 5F5C
h
Parameter | Name:
C00164 | Logbook - analog elements
Data type: UNSIGNED_16
Index: 24411
d
= 5F5B
h
Selection of an analog signal to be logged in the logbook
Selection list
Info
0 No signal
1 AIN1
2 CAN1 control word
3 CAN1 input word 2
4 CAN1 input word 3
5 CAN1 input word 4
6 CAN2 input word 1
7 CAN2 input word 2
8 CAN2 input word 3
9 CAN2 input word 4