8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00274
574
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C00274
C00275
C00276
C00280
C00290
C00291
C00296
C00297
Parameter | Name:
C00274 | SC: Max. change in acceleration
Data type: UNSIGNED_16
Index: 24301
d
= 5EED
h
Limitation of the acceleration change at sensorless control for synchronous motors (
SLPSM
)
• Setting in % of M_Nenn per ms.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
%/ms
400.0
400.0 %/ms
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 10
Parameter | Name:
C00275 | Filter setpoint feedforward control
Data type: UNSIGNED_16
Index: 24300
d
= 5EEC
h
From version 03.00.00
Filter time of the setpoint feedforward control at sensorless vector control (
SLVC
)
• The setpoint feedforward control requires the entry of the moment of inertia in
C00273
.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
ms
1000.0
1.0 ms
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 10
Parameter | Name:
C00276 | SC: Max. output voltage
Data type: UNSIGNED_8
Index: 24299
d
= 5EEB
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
Lenze setting
80
%
99
95 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C00280 | SC: Filter time const. DC detection
Data type: UNSIGNED_16
Index: 24295
d
= 5EE7
h
From version 11.00.00
Setting range
(min. value | unit | max. value)
Lenze setting
1
ms
1000
25 ms
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00290 | RCOM error counter
Data type: UNSIGNED_16
Index: 24285
d
= 5EDD
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00291 | Error type RCOM
Data type: UNSIGNED_8
Index: 24284
d
= 5EDC
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00296 | ICOM error number
Data type: UNSIGNED_16
Index: 24279
d
= 5ED7
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00297 | Counter Receive Error Isr
Data type: UNSIGNED_8
Index: 24278
d
= 5ED6
h
This code is for device-internal use only and must not be written to by the user!