Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
581
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00343
C00343
C00344
Parameter | Name:
C00343 | LP_CanIn decoupling value
Data type: UNSIGNED_16
Index: 24232
d
= 5EA8
h
From version 04.00.00
Definition of the value the process data words are to have in the decoupled state.
Configuring exception handling of the CAN PDOs
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C00343/1
0
LP_CanIn1
:wCtrl DiscVal
C00343/2
0
LP_CanIn1
:wIn2 DiscVal
C00343/3
0
LP_CanIn1
:wIn3 DiscVal
C00343/4
0
LP_CanIn1
:wIn4 DiscVal
C00343/5
0
LP_CanIn2
:wIn1 DiscVal
C00343/6
0
LP_CanIn2
:wIn2 DiscVal
C00343/7
0
LP_CanIn2
:wIn3 DiscVal
C00343/8
0
LP_CanIn2
:wIn4 DiscVal
C00343/9
0
LP_CanIn3
:wIn1 DiscVal
C00343/10
0
LP_CanIn3
:wIn2 DiscVal
C00343/11
0
LP_CanIn3
:wIn3 DiscVal
C00343/12
0
LP_CanIn3
:wIn4 DiscVal
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00344 | LP_CanOut decoupling value
Data type: UNSIGNED_16
Index: 24231
d
= 5EA7
h
From version 04.00.00
Definition of the value the process data words are to have in the decoupled state.
Configuring exception handling of the CAN PDOs
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C00344/1
0
LP_CanOut1
:wState DiscVal
C00344/2
0
LP_CanOut1
:wOut2 DiscVal
C00344/3
0
LP_CanOut1
:wOut3 DiscVal
C00344/4
0
LP_CanOut1
:wOut4 DiscVal
C00344/5
0
LP_CanOut2
:wOut1 DiscVal
C00344/6
0
LP_CanOut2
:wOut2 DiscVal
C00344/7
0
LP_CanOut2
:wOut3 DiscVal
C00344/8
0
LP_CanOut2
:wOut4 DiscVal
C00344/9
0
LP_CanOut3
:wOut1 DiscVal
C00344/10
0
LP_CanOut3
:wOut2 DiscVal
C00344/11
0
LP_CanOut3
:wOut3 DiscVal
C00344/12
0
LP_CanOut3
:wOut4 DiscVal
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com