8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00372
C00372
C00381
C00385
C00386
Parameter | Name:
C00372 | CAN_Tx_Rx_Error
Data type: UNSIGNED_8
Index: 24203
d
= 5E8B
h
System bus "CAN on board"
Display range
(min. value | unit | max. value)
0
255
Subcodes
Info
C00372/1
CAN Tx_Error
C00372/2
CAN Rx_Error
C00372/3
CAN Tx_Overflow
C00372/4
CAN Rx_Overflow
;
Read access
Write access
CINH
PLC STOP
;
No transfer
;
COM
MOT
Scaling factor: 1
Parameter | Name:
C00381 | CAN Heartbeat producer time
Data type: UNSIGNED_16
Index: 24194
d
= 5E82
h
Time interval for the transmission of the heartbeat telegram to the consumer(s).
• The heartbeat telegram is sent automatically as soon as a time > 0 ms is set.
• Imaging of the CANopen object
I-1017
(see DS301 V4.02).
Heartbeat protocol
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
65535
0 ms
;
Read access
;
Write access
CINH
PLC STOP
No transfer
;
COM
MOT
Scaling factor: 1
Parameter | Name:
C00385 | CAN node addr. HeartBeat producer
Data type: UNSIGNED_8
Index: 24190
d
= 5E7E
h
From version 03.00.00
The subcodes represent the nodes to be monitored by heartbeat.
Heartbeat protocol
Setting range
(min. value | unit | max. value)
0
127
Subcodes
Lenze setting
Info
C00385/1
0
CAN node address HeartBeat producer 1 ... 7
C00385/...
C00385/7
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00386 | ConsumerTime HeartBeat producer
Data type: UNSIGNED_16
Index: 24189
d
= 5E7D
h
From version 03.00.00
The subcodes represent the nodes to be monitored by heartbeat.
Heartbeat protocol
Setting range
(min. value | unit | max. value)
0
ms
60000
Subcodes
Lenze setting
Info
C00386/1
0 ms
Consumer time HeartBeat producer 1 ... 7
C00386/...
C00386/7
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1