Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
599
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00444
C00444
C00445
Parameter | Name:
C00444 | DOx: Level
Data type: UNSIGNED_16
Index: 24131
d
= 5E43
h
Bit coded display of the level of the digital outputs
Digital terminals
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Relay
Bit set = HIGH level
Bit 1 DO1
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Subcodes
Info
C00444/1
DOx: Input level
C00444/2
DOx: Terminal level
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Parameter | Name:
C00445 | FreqInxx_nOut_v
Data type: INTEGER_16
Index: 24130
d
= 5E42
h
From version 03.00.00
Display of the frequency input signals which are fed into the application.
Using DI1 and DI2 as frequency inputs
Display range
(min. value | unit | max. value)
-32767
Incr/ms
32767
Subcodes
Info
C00445/1
FreqIn12_nOut_v
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 1