Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
605
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00469
C00469
C00470
C00471
C00472
Parameter | Name:
C00469 | Keypad: STOP key function
Data type: INTEGER_32
Index: 24106
d
= 5E2A
h
Selection of the function for the STOP key on the keypad
Selection list
(Lenze setting printed in bold)
Info
0 No function
STOP key does not have any function
1 Inhibit controller
STOP key sets controller inhibit in the drive
2 Activate quick stop
STOP key sets quick stop in the drive
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00470 | LS_ParFree_b
Data type: UNSIGNED_8
Index: 24105
d
= 5E29
h
The
LS_ParFree_b
SB: Setting of the signal level to be output
Selection list
0 False
1 TRUE
Subcodes
Lenze setting
Info
C00470/1
0: FALSE
Signal level for output
bPar1
...
bPar16
C00470/...
C00470/16
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00471 | LS_ParFree
Data type: UNSIGNED_16
Index: 24104
d
= 5E28
h
The
LS_ParFree
SB: Setting of the words to be output
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Active
... ...
Bit 15 Active
Subcodes
Lenze setting
Info
C00471/1
0
Value for output
wPar1
...
wPar4
C00471/...
C00471/4
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C00472 | LS_ParFree_a
Data type: INTEGER_16
Index: 24103
d
= 5E27
h
The
LS_ParFree_a
SB: Setting of the analog signals to be output
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C00472/1
0.00 %
Value for output
nPar1_a
C00472/2
0.00 %
Value for output
nPar2_a
C00472/3
100.00 %
Value for output
nPar3_a
C00472/4
100.00 %
Value for output
nPar4_a
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com