8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00595
618
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C00595
C00597
Parameter | Name:
C00595 | MCK: Resp. to MCK error
Data type: UNSIGNED_8
Index: 23980
d
= 5DAC
h
Configuration of monitoring of the Motion Control Kernel
Basic drive functions
Selection list
0 No Reaction
1 Fault
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C00595/1
0: No Reaction
Reserved
C00595/2
0: No Reaction
Reserved
C00595/3
0: No Reaction
Reserved
C00595/4
0: No Reaction
Reserved
C00595/5
0: No Reaction
Reserved
C00595/6
0: No Reaction
Reserved
C00595/7
0: No Reaction
Reserved
C00595/8
0: No Reaction
Reserved
C00595/9
0: No Reaction
Reserved
C00595/10
0: No Reaction
Reserved
C00595/11
0: No Reaction
Reserved
C00595/12
0: No Reaction
Reserved
C00595/13
0: No Reaction
Reserved
C00595/14
0: No Reaction
Reserved
C00595/15
1: Fault
Response to activated connection monitoring in case of
PC manual control
•
From version 11.00.00
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00597 | Resp. to motor phase failure
Data type: UNSIGNED_8
Index: 23978
d
= 5DAA
h
Response to motor phase failure
• If a phase current does not exceed the threshold set in
C00599
for more than one period, the response set here
will be triggered.
Selection list
(Lenze setting printed in bold)
0 No Reaction
1 Fault
5 Warning
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com