8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00634
630
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C00634
C00635
C00636
C00637
Parameter | Name:
C00634 | L_NSet_1: wState
Data type: UNSIGNED_16
Index: 23941
d
= 5D85
h
L_NSet_1
FB: Bit coded status display
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 No blocking zone active
"1"
≡
No blocking zone set for constant speeds
Bit 1 Blocking zone 1 active
"1"
≡
Suppression of constant speed characteristics
within the limits of blocking zone 1
Bit 2 Blocking zone 2 active
"1"
≡
Suppression of constant speed characteristics
within the limits of blocking zone 2
Bit 3 Blocking zone 3 active
"1"
≡
Suppression of constant speed characteristics
within the limits of blocking zone 3
Bit 4 Jog in blocking zone
"1"
≡
A ramp is used to keep the speed setpoint within a
speed blocking zone
Bit 5 MaxLimit active
"1"
≡
Speed setpoint is at the maximum speed limit
Bit 6 MinLimit active
"1"
≡
Speed setpoint is at the minimum speed limit
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Parameter | Name:
C00635 | L_NSet_1: nMaxLimit
Data type: INTEGER_16
Index: 23940
d
= 5D84
h
The
L_NSet_1
FB: Maximum speed setpoint for speed setpoint limitation
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99
199.99 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00636 | L_NSet_1: nMinLimit
Data type: INTEGER_16
Index: 23939
d
= 5D83
h
The
L_NSet_1
FB: Minimum speed setpoint for speed setpoint limitation
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99
-199.99 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00637 | L_NSet_1: Output blocking zones
Data type: INTEGER_16
Index: 23938
d
= 5D82
h
The
L_NSet_1
FB: Speed setpoint is displayed after being processed by blocking zone function
Display range
(min. value | unit | max. value)
-199.99
%
199.99
;
Read access
Write access
CINH
PLC STOP
;
No transfer
COM
MOT
Scaling factor: 100