Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
643
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00761
C00761
C00760/15
0: Not connected
LA_SwitchPos
: nGPCompareIn1_a
(input for comparison operation analog signal 1)
C00760/16
0: Not connected
LA_SwitchPos
: nGPCompareIn2_a
(input for comparison operation analog signal 2)
C00760/17
0: Not connected
LA_SwitchPos
: wSMCtrl
(interface to optional safety system)
C00760/18
0: Not connected
Reserved
C00760/19
0: Not connected
Reserved
C00760/20
0: Not connected
Reserved
C00760/21
0: Not connected
Reserved
C00760/22
0: Not connected
LA_SwitchPos
: wFreeIn1
(input for user signal 1)
C00760/23
0: Not connected
LA_SwitchPos
: wFreeIn2
(input for user signal 2)
C00760/24
0: Not connected
LA_SwitchPos
: wFreeIn3
(input for user signal 3)
C00760/25
0: Not connected
LA_SwitchPos
: wFreeIn4
(input for user signal 4)
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00760 | LA_SwitchPos: Analog connection list
Data type: UNSIGNED_16
Index: 23815
d
= 5D07
h
Parameter | Name:
C00761 | LA_SwitchPos: Digital connection list
Data type: UNSIGNED_16
Index: 23814
d
= 5D06
h
Connection parameters for "Switch-off positioning" application: Binary inputs
• Selection of the binary output signals to be connected to the binary input signals
• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See
selection list - digital signals
Subcodes
Lenze setting
Info
C00761/1
0: Not connected
LA_SwitchPos
: bCInh
(control input for setting controller inhibit)
C00761/2
0: Not connected
LA_SwitchPos
: bFailReset
(control input for error acknowledgement)
C00761/3
0: Not connected
LA_SwitchPos
: bSetQuickstop
(control input for quick stop request)
C00761/4
0: Not connected
LA_SwitchPos
: bSetDCBrake
(control input for DC-injection braking request)
C00761/5
0: Not connected
LA_SwitchPos
: bRFG_Stop
(control input for stopping the speed ramp function
generator)
C00761/6
0: Not connected
LA_SwitchPos
: bSetSpeedCcw
(control input for change of direction of rotation)
C00761/7
0: Not connected
LA_SwitchPos
: bRLQCw
(control input for activation of CW rotation (fail-safe))
C00761/8
0: Not connected
LA_SwitchPos
: bRLQCcw
(control input for activation of CCW rotation (fail-safe))
C00761/9
0: Not connected
LA_SwitchPos
: bJogCtrlInputSel1
(selection input 1 for binary coded selection of the
switch-off position 1 ... 3)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com