Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
65
8400 StateLine C | Reference manual
Commissioning
Commissioning of the "Switch-off positioning" technology application
3.7.3
Parameterising the motor control
1. Go to
Workspace
and change to the
Application parameters
tab.
– The motor control parameters, among other things, can be found on the left:
2. In the
Motor control
list field (
C00006
), select the desired motor control.
3. Adapt the motor control parameters:
Related topics:
Notes on motor control
(
49)
Motor control (MCTRL)
(
106)
Parameter
Lenze setting
Info
Value Unit
V/f base frequency
(
C00015
)
50.0 Hz
Adapting the V/f base frequency (
132)
Imax in motor mode
(
C00022
)
47.00 A
Optimising the Imax controller (
136)
Vmin boost
(
C00016
)
1.60 %
Adapting the Vmin boost (
134)
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com