Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
677
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00985
C00985
C00986
C00987
C00988
C00990
Parameter | Name:
C00985 | SLVC: Field current controller gain
Data type: INTEGER_16
Index: 23590
d
= 5C26
h
Gain of the direct-axis current difference (Id) between setpoint and actual current for the voltage model of the
sensorless vector control (
SLVC
)
• The gain should be selected in a range of 0 ...1 %.
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
10.00
0.50 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00986 | SLVC: Cross current controller gain
Data type: INTEGER_16
Index: 23589
d
= 5C25
h
Gain of the cross current difference for the voltage model of the sensorless vector control (
SLVC
)
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
10.00
0.00 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00987 | Inverter motor brake: nAdd
Data type: INTEGER_16
Index: 23588
d
= 5C24
h
From version 04.00.00
Speed lift which is connected in pulses to the brake rampe when the motor is braked.
Inverter motor brake
Setting range
(min. value | unit | max. value)
Lenze setting
0
rpm
1000
80 rpm
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C00988 | Inverter motor brake: PT1 filter time
Data type: INTEGER_16
Index: 23587
d
= 5C23
h
From version 04.00.00
PT1 filter time for smoothing the speed lift which is added in pulses (
C00987
)
Inverter motor brake
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
ms
100.0
0.0 ms
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 10
Parameter | Name:
C00990 | Flying restart fct.: Activation
Data type: UNSIGNED_8
Index: 23585
d
= 5C21
h
Switch on/activate flying restart circuit for non-feedback drive systems
Flying restart fct.
Selection list
(Lenze setting printed in bold)
0 Off
1 On
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1