Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
679
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00995
C00995
C00996
C00997
C00998
C00999
Parameter | Name:
C00995 | SLPSM: Controlled current setpoint
Data type: UNSIGNED_16
Index: 23580
d
= 5C1C
h
From version 10.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
5.00
%
400.00
Subcodes
Lenze setting
Info
C00995/1
100.00 %
SLPSM
: Controlled accelerating current
C00995/2
20.00 %
SLPSM
: Controlled standstill current
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 100
Parameter | Name:
C00996 | SLPSM: Switching speed
Data type: INTEGER_16
Index: 23579
d
= 5C1B
h
From version 10.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C00996/1
13.00 %
SLPSM
: Switching speed, closed-loop control
C00996/2
8.00 %
SLPSM
: Switching speed, open-loop control
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00997 | SLPSM: Filter cutoff frequency
Data type: INTEGER_16
Index: 23578
d
= 5C1A
h
From version 10.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00
5.00 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00998 | SLPSM: Filter time rotor position
Data type: INTEGER_16
Index: 23577
d
= 5C19
h
From version 10.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
0.5
ms
20.0
Subcodes
Lenze setting
Info
C00998/1
3.0 ms
SLPSM
: Filter time rotor position
C00998/2
5.0 ms
SLPSM
: Filter time actual speed value
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 10
Parameter | Name:
C00999 | SLPSM: PLL gain
Data type: INTEGER_16
Index: 23576
d
= 5C18
h
From version 10.00.00
Sensorless control for synchronous motor
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
1000
400 %
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com